This study provides a framework for robust hand grasp type classification during dynamic arm position changes by improving both the hardware and algorithm components. Experimental results showed that the classification accuracy of multi-modal EMG-FMG signals was increased by more than 10% compared with the EMG-only signal, and the proposed sequential decision algorithm improved the accuracy by more than 4% compared with other baseline models when using both EMG and FMG signals.
Robust classification of natural hand grasp type based on electromyography (EMG) still has some shortcomings in the practical prosthetic hand control, owing to the influence of dynamic arm position changing during hand actions. This study provided a framework for robust hand grasp type classification during dynamic arm position changes, improving both the hardware and algorithm components. In the hardware aspect, co-located synchronous EMG and force myography (FMG) signals are adopted as the multi-modal strategy. In the algorithm aspect, a sequential decision algorithm is proposed by combining the RNN-based deep learning model with a knowledge-based post-processing model. Experimental results showed that the classification accuracy of multi-modal EMG-FMG signals was increased by more than 10% compared with the EMG-only signal. Moreover, the classification accuracy of the proposed sequential decision algorithm improved the accuracy by more than 4% compared with other baseline models when using both EMG and FMG signals.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据