4.8 Article

An implantable biomechanical energy harvester for animal monitoring devices

期刊

NANO ENERGY
卷 98, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.nanoen.2022.107290

关键词

Implantable devices; Piezoelectric energy harvester; Reliability; Failure analysis; Macro Fiber Composite

资金

  1. U.S. Department of Energys Office of Technology Transitions and Water Power Technologies Office
  2. Pa-cific Northwest National Laboratory LDRD Program

向作者/读者索取更多资源

Insufficient service life and the need for battery replacements are major challenges for implantable electronic devices. To address this issue, researchers have developed a biomechanical energy harvester that uses animals' body bending movements to power implantable and wearable devices. Experiments using fish as test subjects have shown successful signal transmissions for up to 5 weeks, but the limited lifespan of the energy harvester remains a constraint.
Insufficient service life and the resulting need for battery replacements have been a great challenge for implantable electronic devices. This is particularly true for animal tracking applications, because recapturing animals is often unlikely once they are released to the wild. To tackle this problem, we developed a biomechanical energy harvester that uses a Macro Fiber CompositeTM (MFC) piezoelectric beam to harvest the mechanical energy from animals' body bending movements as the power source for implantable and wearable devices. Prototypes of an underwater acoustic transmitter using this technology were subdermally implanted into juvenile white sturgeon and their energy harvesting performance was evaluated through the devices' transmissions. The fish successfully recovered from the implantation surgery and freely swam inside a tank. The transmitter prototypes in the fish continually transmitted signals for a period up to 5 weeks. A benchtop test setup was also created to emulate the fish's body bending, estimate the device's energy harvesting performance in the live fish, and perform accelerated fatigue testing of the energy harvester by applying test parameters learned from a video study of the fish's body movement and behavior characteristics. The gradual depolarization of the piezoelectric ceramic material in the MFC under cyclic mechanical loading was the main limiting factor for the life span of the energy harvester. Pathways for improvement are proposed to achieve long-term efficacy of powering implantable and wearable electronic devices.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据