4.6 Article

DeepCNAP: A Deep Learning Approach for Continuous Noninvasive Arterial Blood Pressure Monitoring Using Photoplethysmography

期刊

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JBHI.2022.3172514

关键词

Deep learning; Estimation; Feature extraction; Data models; Convolution; Monitoring; Hypertension; Deep learning; self-attention; arterial blood pressure; photoplethysmography; hemodynamic instability

资金

  1. National Research Foundation of Korea (NRF) - Korean Government (Ministry of Science and ICT, MSIT) [2019R1A2C1003399]
  2. Korea Medical Device Development Fund - Korea Government (Ministry of Science and ICT) [1711139120, KMDF_PR_20210528_0001]
  3. Korea Medical Device Development Fund - Korea Government (Ministry of Trade, Industry and Energy) [1711139120, KMDF_PR_20210528_0001]
  4. Korea Medical Device Development Fund - Korea Government (Ministry of Health Welfare) [1711139120, KMDF_PR_20210528_0001]
  5. Korea Medical Device Development Fund - Korea Government (Ministry of Food and Drug Safety) [1711139120, KMDF_PR_20210528_0001]

向作者/读者索取更多资源

This article introduces a novel deep learning model, DeepCNAP, which can estimate continuous blood pressure waveform in real time from noninvasively measured photoplethysmography signals. The model demonstrates good performance in blood pressure estimation and classification of hemodynamically stable events.
Arterial blood pressure (ABP) monitoring may permit the early diagnosis and management of cardiovascular disease (CVD); however, existing methods for measuring ABP outside the clinic use inconvenient cuff sphygmomanometry, or do not estimate continuous ABP waveforms. This study proposes a novel deep learning model DeepCNAP for estimating continuous BP waveform from a noninvasively measured photoplethysmography (PPG) signal in real-time. DeepCNAP was designed through the combination of deep convolutional networks and self-attention. The proposed method was constructed via 10-fold cross-validation based on the MIMIC database (the number of subjects = 942, recording time = 374.43 hours). The performance of DeepCNAP was evaluated from two perspectives: estimating ABP from PPG and classifying hemodynamically unstable events (i.e., hypertension, prehypertension, hypotension, and the normal state). The mean absolute errors of the BP estimates were 3.40 +/- 4.36 mmHg for systolic BP, 1.75 +/- 2.25 mmHg for diastolic BP, and 3.23 +/- 2.21 mmHg for the BP waveform, indicating that DeepCNAP satisfies the standards of both the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). From the estimated BP, hypertension, prehypertension, hypotension, and the normal state were classified with 99.44, 97.58, 92.23, and 94.64% accuracy, respectively. DeepCNAP enables feasible real-time estimation of invasively measured ABP from noninvasive PPG. With its noninvasive nature, high accuracy, and clinical relevance, the proposed model could be valuable in general wards at hospitals and for wearable devices in daily life.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据