4.3 Article

Passive wrist deviation to increase the ultrasound identified procedural safe zone in carpal tunnel syndrome: A retrospective cohort study

期刊

PM&R
卷 15, 期 7, 页码 847-852

出版社

WILEY
DOI: 10.1002/pmrj.12876

关键词

-

向作者/读者索取更多资源

This study demonstrates that the ultrasound-measured interstructural safe zone distance was significantly greater in the ulnarly deviated position than in either the neutral position or radially deviated position. These findings may have important implications for improving the safety of ultrasound-guided injections.
Introduction Carpal tunnel syndrome (CTS) is the most common peripheral nerve entrapment syndrome. Although prior studies have explored the anatomic changes of the median nerve and carpal arch with different wrist deviations and positionings, the change in safe zone distance between the median nerve and ulnar artery with ulnar or radial wrist deviations has not been adequately investigated. Objective To identify the optimal wrist positioning that increases the safe zone distance between the median nerve and ulnar artery using ultrasound in patients with CTS. Design Retrospective cohort study. Setting Quaternary medical center multidisciplinary outpatient hand clinic. Participants Twenty five patients (41 wrists) with clinical CTS who received an electrodiagnostic study (EDX) to evaluate CTS within 1 year prior to enrollment. Interventions Ultrasound-identified safe zone distance measurements were obtained in each patient between the ulnar aspect of the median nerve and the radial aspect of the ulnar artery with the wrist in neutral radial-ulnar deviation as well as in passive ulnar and radial deviation. Main Outcome Measure The ultrasound-identified safe zone distance with the wrist in each of the three positions. Results The interstructural safe zone distance was significantly greater when measured in the ulnarly deviated position (1.08 cm) compared with either the neutral (0.61cm, p < .001) or radially deviated positions (0.52 cm, p < .001). Interstructural safe zone distance did not differ between those with normal, mild, moderate, or severe classifications of pathology, or between dominant and nondominant limbs. Conclusion This study demonstrates that the ultrasound-measured interstructural safe zone distance was significantly greater in the ulnarly deviated position than in either the neutral position or radially deviated position. These findings may lead to improvement in the safety of ultrasound-guided injections.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据