4.5 Article

Approach to optimal assessment of right ventricular remodelling in heart transplant recipients: insights from myocardial work index, T1 mapping, and endomyocardial biopsy

期刊

出版社

OXFORD UNIV PRESS
DOI: 10.1093/ehjci/jeac108

关键词

heart transplantation; right ventricle; strain; myocardial work; cardiac magnetic resonance; T1 mapping

向作者/读者索取更多资源

This study aimed to investigate the relative merits of echocardiography and cardiac magnetic resonance (CMR) with T1 mapping for the assessment of functional adaptation and remodelling of the right ventricle (RV) in heart transplant recipients. The study found that echocardiographic parameters can reflect changes in cardiac function and structure in patients, while CMR is better at reflecting changes in myocardial microstructure.
Aims Right ventricular (RV) dysfunction is an important cause of graft failure after heart transplantation (HTx). We sought to investigate relative merits of echocardiographic tools and cardiac magnetic resonance (CMR) with T1 mapping for the assessment of functional adaptation and remodelling of the RV in HTx recipients. Methods and results Sixty-one complete data set of echocardiography, CMR, right heart catheterization, and biopsy were obtained. Myocardial work index (MWI) was quantified by integrating longitudinal strain (LS) with invasively measured pulmonary artery pressure. CMR derived RV volumes, T1 time, and extracellular volume (ECV) were quantified. Endomyocardial biopsy findings were used as the reference standard for myocardial microstructural changes. In HTx recipients who never had a previous allograft rejection, longitudinal function parameters were lower than healthy organ donors, while ejection fraction (EF) (52.0 +/- 8.7%) and MWI (403.2 +/- 77.2 mmHg%) were preserved. Rejection was characterized by significantly reduced LS, MWI, longer T1 time, and increased ECV that improved after recovery, whereas RV volumes and EF did not change MWI was the strongest determinant of rejection related myocardial damage (area under curve: 0.812, P < 0.0001, 95% CI: 0.69-0.94) with good specificity (77%), albeit modest sensitivity. In contrast, T1 time and ECV were sensitive (84%, both) but not specific to detect subclinical RV damage. Conclusion Subclinical adaptive RV remodelling is characterized by preserved RV EF despite longitudinal function abnormalities, except for MWI. While ultrastructural damage is reflected by MWI, ECV, and T1 time, only MWI has the capability to discriminate functional adaptation from transition to subclinical structural damage.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据