4.6 Article

Establishment and validation of a UPLC-MS/MS bioassay for the quantification of infigratinib in rat plasma

期刊

ARABIAN JOURNAL OF CHEMISTRY
卷 15, 期 7, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.arabjc.2022.103893

关键词

Infigratinib; SD rat; UPLC-MS; MS; Pharmacokinetics

资金

  1. National Key Research and Development Program of China [2020YFC2008301]

向作者/读者索取更多资源

This study optimized an analytical method using UPLC-MS/MS for the determination of Infigratinib concentrations in rat plasma and pharmacokinetic studies. The method demonstrated high linearity and accuracy, with good reproducibility and rapidity.
Infigratinib (INF) is a fibroblast growth factor receptor (FGFR)-specific tyrosine kinase inhibitor for the therapy of advanced cholangiocarcinoma. However, CYP3A4 polymorphisms and CYP3A4 inducers or inhibitors might affect the pharmacokinetics of INF. Clinical evaluation of drug-drug interactions and adverse effects in these patients was necessary with reference to INF levels in vivo. The presently conducted study optimized a reproducible and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) analytic technique, which was validated and applied to determine INF concentrations in Sprague-Dawley (SD) rat plasma and pharmacokinetic studies. Protein was precipitated by adding acetonitrile to plasma samples, followed by gradient elution on a Waters Acquity UPLC BEH C18 column (2.1 mm x 50 mm, 1.7 lm) for complete chromatographic separation of the analyte and derazantinib (used as internal standard, IS). A gradient elution of 0.1% formic acid aqueous solution and acetonitrile at a flow rate of 0.30 mL/min was applied as the mobile phase for this analysis. The ion transitions of INF and IS were m/z 599.88-> 313.10 and m/z 468.96-> 382.00 during UPLCMS/MS detection, respectively, by multiple reaction monitoring (MRM). The methodological validation demonstrated that INF presented high linearity over the concentration of 2-600 ng/mL. The lower limit of quantification (LLOQ) for this experiment was 2 ng/mL, of which the precisions and accuracies were within the permissible levels. Inter-day and intra-day precisions were demonstrated to be within reasonable limits, which were within 15%, and the accuracies were determined to be between 2.2% and 11.4%. Moreover, the values of recovery, stability and matrix effect of INF were within the limits of acceptability. The pharmacokinetics of INF in SD rats was investigated by gav-age administration of 10 mg/kg INF, followed by the application of the developed UPLC-MS/MS analytical method to detect the content in plasma and derive the main pharmacokinetic parameters.(c) 2022 The Author(s). Published by Elsevier B.V. on behalf of King Saud University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据