4.5 Article

High-Sensitivity Demodulation of Fiber-Optic Acoustic Emission Sensor Using Self-Injection Locked Diode Laser

期刊

IEEE PHOTONICS JOURNAL
卷 14, 期 4, 页码 -

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JPHOT.2022.3192806

关键词

Optical fiber sensors; Laser mode locking; Fiber lasers; Laser feedback; Optical fiber polarization; Optical fiber couplers; Optical resonators; Fiber Bragg gratings; laser self-injection locking; Fabry-Perot interferometer; phase-generated carrier demodulation; ultrasonic sensors; fiber-optic sensors; structural health monitoring

资金

  1. Office of Naval Research [N000141812273, N000142112273, N000141812597]
  2. U.S. Department of Defense (DOD) [N000141812273, N000142112273, N000141812597] Funding Source: U.S. Department of Defense (DOD)

向作者/读者索取更多资源

In this study, a self-injection locked distributed feedback diode laser and a fiber-coil Fabry-Perot interferometer sensor were used for high-sensitivity detection of acoustic emission. Improved demodulation method and identification of mode-hopping events were employed to enhance the signal-to-noise ratio and reduce spurious signals.
We demonstrate the use of a self-injection locked distributed feedback (DFB) diode laser for high-sensitivity detection of acoustic emission (AE) using a fiber-coil Fabry-Perot interferometer (FPI) sensor. The FPI AE sensor is formed by two weak fiber Bragg gratings on the ends of a long span of coiled fiber, resulting in dense sinusoidal fringes in its reflection spectrum that allows the use of a modified phase-generated carrier demodulation method. The demodulation method does not require agile tuning capability of the laser, which makes the self-injection locked laser particularly attractive for the application. Experimental results indicate that the self-injection locked laser increases the signal-to-noise ratio by similar to 33 dB compared with the free-running DFB laser. We studied the mode-hopping and laser instability of the self-injection locked laser and their effect on the demodulated signal and found that a mode hopping event causes an abrupt change in the laser intensity after the resonator inside the feedback loop. It manifests itself as a short transient signal in the output of the AE sensor system. With the identification of the mode-hopping events, the associated spurious signal can be identified and discarded in the signal processing without causing significant disruption to the sensor system. Experiment shows that the frequency of locked lasers could oscillate during unstable operations. The fundamental frequency is determined by the time delay of the feedback light and is typically much larger than the AE frequency. Therefore, the laser frequency oscillations have no negative effect on the performance of the sensor system. Finally, we show that the frequency of mode-hopping occurrence is related to the length of the feedback loop and reducing the loop length can effectively reduce the frequency of mode-hopping occurrence.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据