3.8 Article

Electrochemical Glucose Sensing Using Molecularly Imprinted Polyaniline-Copper Oxide Coated Electrode

期刊

出版社

PLEIADES PUBLISHING INC
DOI: 10.3103/S1068375522030127

关键词

electrochemical sensor; polyaniline; molecular imprinting; glucose; non-enzymatic

资金

  1. National Institute of Technology Calicut, Kerala, India [FRG/2019]

向作者/读者索取更多资源

This research has made significant progress in blood glucose monitoring for diabetic patients. By developing a non-enzymatic electrochemical sensor, non-invasive detection of glucose has been achieved. The electrode, which combines the features of molecularly imprinted polymers and high conductivity, increases selectivity towards glucose sensing.
Diabetes is a chronic condition in which the body cannot produce or effectively utilize the produced insulin. Insulin is a hormone that regulates the blood glucose level (BGL). The long-term increased BGL can have serious health effects. Time-based monitoring of BGL is necessary for diabetic patients to avoid severe health conditions. For this purpose, a non-enzymatic electrochemical sensor for the non-invasive detection of glucose was prepared and tested in the framework of this research. The sensor was developed by combining the features of a molecularly imprinted polymer (MIP) and the highly conductive nature of polyaniline (PANI) and copper oxide nanoparticles (CuONPs). The CuONPs were electrodeposited onto the bare graphite electrode in the presence of 1.8 M H2SO4 solution. Using aniline as the monomer in presence of 0.5 M H2SO4, the copper oxide-coated pencil graphite electrode was electropolymerized to obtain a non-imprinted polyaniline/copper oxide-coated graphite electrode. Glucose was added to the electrolytic solution for the preparation of a molecularly imprinted polymer electrode. Cyclic voltammetry and amperometry were used to characterize the electrochemical response of the modified electrode in the presence and in the absence of glucose, as well as the selectivity of the sensor towards glucose detection in the presence of the interfering species. The morphological characterization of the fabricated electrode was investigated using scanning electron microscopy, Fourier transform-infrared spectroscopy, 3D surface profilometry, X-ray diffraction spectroscopy, and goniometry. From the electrochemical and morphological characterization results, it was inferred that the modified graphite electrode possesses imprinted sites, which helps to increase selectivity towards glucose sensing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据