4.7 Article

An omnidirectional piezoelectric transducer for selective excitation and reception of high-order shear horizontal waves

期刊

ULTRASONICS
卷 124, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.ultras.2022.106731

关键词

Shear horizontal wave; Guided wave; Omnidirectional; Piezoelectric transducers; Structural health monitoring

资金

  1. National Natural Science Foundation of China [11890684]

向作者/读者索取更多资源

This study proposes a general method for designing an OSH1-PT based on the thickness-poled PZT half-ring configuration. The excitation function of the OSH1-PT is derived and validated through finite element simulations. The designed OSH1-PT is fabricated and tested using a 2D laser Doppler vibrometer, demonstrating significant mode selectivity in all directions. The proposed method paves the way for wide applications of high-order SH wave tomography.
Guided wave tomography, as an advanced structural health monitoring (SHM) method, has offered a feasible solution to wall thickness quantification which is essential in petrochemical industries. However, previously used low-frequency Lamb waves (A(0) and S-0) limit the resolution of tomography. Recently, the first-order shear horizontal guided wave (SH1) was found very promising in tomography for its capability in resolution improvement. However, the SHM-required omnidirectional piezoelectric transducers for selectively generating and receiving the SH1 wave, namely OSH1-PT, are not available yet. In this work, a general method was developed to design an OSH1-PT based on the thickness-poled PZT half-ring configuration. Firstly, the excitation function of the OSH1-PT was explicitly derived and validated through finite element simulations. Secondly, a design formula was obtained and used to determine the size of the OSH1-PT. Then, the designed OSH1-PT was fabricated and tested by using a 2D laser Doppler vibrometer. Significant mode selectivity was observed in all directions (0 similar to 90 degrees) with the excited SH1 to SH0 ratio higher than 15 dB. Pitch-catch tests were conducted from 400 similar to 520 kHz and the received SH1 to SH0 ratio was found higher than 19 dB at all frequencies and reached its maxima of 30.7 dB at 490 kHz, which is very close to the designed working frequency of 500 kHz. Finally, an OSH2-PT was theoretically designed and validated by FE simulations. Due to its simplicity and effectiveness in designing the OSHn-PT, the proposed method is expected to pave the road to wide applications of high-order SH wave tomography.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据