4.2 Article

Relative and absolute reliability of shank and sacral running impact accelerations over a short- and long-term time frame

期刊

SPORTS BIOMECHANICS
卷 -, 期 -, 页码 -

出版社

ROUTLEDGE JOURNALS, TAYLOR & FRANCIS LTD
DOI: 10.1080/14763141.2022.2086169

关键词

Kinetics; load monitoring; tibia

资金

  1. Science Foundation Ireland (SFI) [DCUREC/2019/127]
  2. European Regional Development Fund

向作者/读者索取更多资源

This study aimed to assess the reliability of shank and sacral impact accelerations over short- and long-term time periods. The results showed that the measurement of impact acceleration at the shank and sacrum had high relative reliability and moderate absolute reliability across different speeds and exertion levels. However, the minimal detectable change of the measurements was large, indicating limited use in intervention studies.
Whilst running is hugely popular, running-related injuries (RRIs) are prevalent. High impact loading has been proposed to contribute to RRIs, with accelerometers becoming increasingly popular in estimating segmental loading for injury detection and biofeedback training. However, there is a lack of research examining the reliability of measures of impact acceleration across short- and long-term time periods, both prior to and following exerted running. The aim of this study was to assess the absolute and relative reliability of shank and sacral impact accelerations over a short- and long-term time period. Peak (Peak(accel)) and rate (Rate(accel)) of impact acceleration at the shank and sacrum were assessed in 18 recreational runners over short- and long-term time frames, across fixed and self-selected speeds. The relative and absolute reliabilities were investigated for pre- and post-exerted states of running. There was high-to-excellent relative reliability, and predominantly moderate absolute reliability for shank and sacrum Peak(accel) and Rate(accel) in the short- and long-term time frames between pre- and post-exerted states. High to excellent relative reliability of Peak(accel) and Rate(accel) at the shank and sacrum are appropriate and acceptable measures across short- and long-term time frames. These findings were consistent with different levels of speed and exertion. The minimal detectable change % was large for both sensors and associated measurements, indicating that their use may be limited to intervention studies that elicit large change (>30%) in these measures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据