4.6 Article

Easy-Scalable Flexible Sensors Made of Carbon Nanotube-Doped Polydimethylsiloxane: Analysis of Manufacturing Conditions and Proof of Concept

期刊

SENSORS
卷 22, 期 14, 页码 -

出版社

MDPI
DOI: 10.3390/s22145147

关键词

carbon nanotubes; stretchable sensors; PDMS; human motion monitoring

资金

  1. Agencia Estatal de Investigacion of Spanish Government [MULTIFUNC-EVs PID2019-107874RB-I00]
  2. Comunidad de Madrid Government [S2018/NMT-4411]

向作者/读者索取更多资源

Carbon nanotube reinforced polydimethylsiloxane sensors for human motion monitoring are proposed. The dispersion of nanoparticles into the polymer matrix using ultrasonication provides higher electrical sensitivity compared to three-roll milling. The optimum conditions for the sensors were determined at 0.4 CNT wt.% dispersed by ultrasonication, providing high robustness and applicability.
Carbon nanotube (CNT) reinforced polydimethylsiloxane (PDMS) easy-scalable sensors for human motion monitoring are proposed. First, the analysis of the dispersion procedure of nanoparticles into the polymer matrix shows that the ultrasonication (US) technique provides a higher electrical sensitivity in comparison to three-roll milling (3RM) due to the higher homogeneity of the CNT distribution induced by the cavitation forces. Furthermore, the gauge factor (GF) calculated from tensile tests decreases with increasing the CNT content, as the interparticle distance between CNTs is reduced and, thus, the contribution of the tunnelling mechanisms diminishes. Therefore, the optimum conditions were set at 0.4 CNT wt.% dispersed by US procedure, providing a GF of approximately 37 for large strains. The electrical response under cycling load was tested at 2%, 5%, and 10% strain level, indicating a high robustness of the developed sensors. Thus, this strain sensor is in a privileged position with respect to the state-of-the-art, considering all the characteristics that this type of sensor must accomplish: high GF, high flexibility, high reproducibility, easy manufacturing, and friendly operation. Finally, a proof-of-concept of human motion monitoring by placing a sensor for elbow and finger movements is carried out. The electrical resistance was found to increase, as expected, with the bending angle and it is totally recovered after stretching, indicating that there is no prevalent damage and highlighting the huge robustness and applicability of the proposed materials as wearable sensors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据