4.7 Article

Contrast-enhanced 4D-MRI for internal target volume generation in treatment planning for liver tumors

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Oncology

Local Control After Stereotactic Body Radiation for Liver Tumors

Pelvis Nitin Ohri et al.

Summary: The study evaluated local control rates after SBRT for primary and metastatic liver tumors. Results showed high rates of durable local control for primary liver tumors with no clear dose-response relationship, while better outcomes were observed for liver metastases treated with higher BEDs.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Slice-stacking T2-weighted MRI for fast determination of internal target volume for liver tumor

Silu Han et al.

Summary: The study investigates the feasibility of using slice-stacking MRI technique to generate MIP images for determining ITV. Results show that it is feasible to generate a fast clinically acceptable ITV using this method.

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients

Lei Zhang et al.

Summary: The MC-4D-MRI technique developed in this study expands single image contrast 4D-MRI to a spectrum of native and synthetic image contrasts, showing enhancements in image contrast variety, tumor contrast, and ITV contouring consistencies in liver tumor patients. This technique offers new perspectives on the image contrast of MRI and 4D-MRI in MR-guided radiotherapy.

MEDICAL PHYSICS (2021)

Article Engineering, Biomedical

Validation of a 4D-MRI guided liver stereotactic body radiation therapy strategy for implementation on the MR-linac

Tessa N. van de Lindt et al.

Summary: The 4D-MRI guided strategy demonstrated excellent performance in all workflow tests, including 4D-MRI scanning, tumor registration with CT images, calculation of daily tumor mid-position misalignment, plan adaptation, and adapted plan delivery, in preparation for clinical introduction on the Unity MR-linac.

PHYSICS IN MEDICINE AND BIOLOGY (2021)

Article Oncology

Experimental evaluation of four-dimensional Magnetic Resonance Imaging for radiotherapy planning of lung cancer

Terry Perkins et al.

Summary: Radiotherapy planning for lung cancer typically involves 3D and 4D CT scans to consider respiratory motion. This study evaluated the use of 4D-MRI with self-navigation as an alternative with potential viability for lung cancer treatment planning. Results showed no significant difference in tumor motion range between 4D-MRI and 4D-CT, suggesting the reliability of 4D-MRI in this context.

PHYSICS & IMAGING IN RADIATION ONCOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of End-Expiration Versus End-Inspiration Breath-Holds With Respect to Respiratory Motion Artifacts on TI-Weighted Abdominal MRI

Kim-Nhien Vu et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2019)

Article Oncology

Retrospective self-sorted 4D-MRI for the liver

Tessa N. van de Lindt et al.

RADIOTHERAPY AND ONCOLOGY (2018)

Review Engineering, Biomedical

Nuts and bolts of 4D-MRI for radiotherapy

B. Stemkens et al.

PHYSICS IN MEDICINE AND BIOLOGY (2018)

Review Engineering, Biomedical

MRI-guidance for motion management in external beam radiotherapy: current status and future challenges

C. Paganelli et al.

PHYSICS IN MEDICINE AND BIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning

Joshua N. Freedman et al.

INVESTIGATIVE RADIOLOGY (2017)

Article Engineering, Biomedical

Synthetic CT for MRI-based liver stereotactic body radiotherapy treatment planning

Jeremy S. Bredfeldt et al.

PHYSICS IN MEDICINE AND BIOLOGY (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

XD-GRASP: Golden-Angle Radial MRI with Reconstruction of Extra Motion-State Dimensions Using Compressed Sensing

Li Feng et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Article Chemistry, Physical

Edge sharpness assessment by parametric modeling: Application to magnetic resonance imaging

Rizwan Ahmad et al.

CONCEPTS IN MAGNETIC RESONANCE PART A (2015)

Article Oncology

Optimizing 4-Dimensional Magnetic Resonance Imaging Data Sampling for Respiratory Motion Analysis of Pancreatic Tumors

Bjorn Stemkens et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

ECG and Navigator-Free Four-Dimensional Whole-Heart Coronary MRA for Simultaneous Visualization of Cardiac Anatomy and Function

Jianing Pang et al.

MAGNETIC RESONANCE IN MEDICINE (2014)

Article Oncology

Respiratory Amplitude Guided 4-Dimensional Magnetic Resonance Imaging

Yanle Hu et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Respiration-based sorting of dynamic MRI to derive representative 4D-MRI for radiotherapy planning

Erik Tryggestad et al.

MEDICAL PHYSICS (2013)

Review Gastroenterology & Hepatology

Primovist, Eovist: What to expect?

Bernard E. Van Beers et al.

JOURNAL OF HEPATOLOGY (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Respiratory and Cardiac Self-Gated Free-Breathing Cardiac CINE Imaging With Multiecho 3D Hybrid Radial SSFP Acquisition

Jing Liu et al.

MAGNETIC RESONANCE IN MEDICINE (2010)

Article Oncology

Adaptive Management of Liver Cancer Radiotherapy

Kristy K. Brock et al.

SEMINARS IN RADIATION ONCOLOGY (2010)

Article Oncology

Three-dimensional motion of liver tumors using cine-magnetic resonance imaging

Anna Kirilova et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2008)

Article Engineering, Biomedical

4D MR imaging of respiratory organ motion and its variability

M. von Siebenthal et al.

PHYSICS IN MEDICINE AND BIOLOGY (2007)

Article Computer Science, Interdisciplinary Applications

An optimal radial profile order based on the golden ratio for time-resolved MRI

Stefanie Winkelmann et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2007)

Article Oncology

Partial volume tolerance of the liver to radiation

LA Dawson et al.

SEMINARS IN RADIATION ONCOLOGY (2005)

Article Radiology, Nuclear Medicine & Medical Imaging

Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI

AC Larson et al.

MAGNETIC RESONANCE IN MEDICINE (2005)

Article Radiology, Nuclear Medicine & Medical Imaging

Quantitation of respiratory motion during 4D-PET/CT acquisition

SA Nehmeh et al.

MEDICAL PHYSICS (2004)

Article Oncology

Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy

Y Seppenwoolde et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2002)

Article Oncology

Determination of ventilatory liver movement via radiographic evaluation of diaphragm position

JM Balter et al.

INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS (2001)