4.3 Article

Mechanisms of performance degradation in a double-suction centrifugal pump under inflow distortions

出版社

SAGE PUBLICATIONS LTD
DOI: 10.1177/09544089221104776

关键词

Double-suction pump; bent inlet pipe; inflow distortion; pressure fluctuation; low-frequency disturbance

向作者/读者索取更多资源

This study investigates the impact of primary geometric parameters of inlet pipes on the performance and pressure fluctuations of a centrifugal pump. Experimental measurements and numerical simulations reveal that the bending of the inlet pipes significantly reduces the pump head and efficiency, with a larger corner angle and smaller turning radius leading to greater performance loss. The bending of the inlet pipes also induces pressure imbalance and low-frequency disturbance in the suction chamber. The findings suggest that minimizing the corner angle and installing a long straight pipe downstream of the elbow can mitigate the negative effects of bent inlet pipes on pump performance and pressure fluctuations.
Inlet pipes of the centrifugal pump are generally bent to fit in the limited installation space, which can cause inflow distortions for two sides of the double-suction impeller. This study aimed to understand the effect of primary geometric parameters of inlet pipes, including corner angle, straight pipe length downstream of elbow, and turning radius, on pump performance and pressure fluctuations. The pump head, efficiency, and pressure fluctuations were measured for six kinds of inlet pipes in the experiment. Unsteady numerical simulations were performed to understand the flow mechanisms. Results indicate that the bending of inlet pipes is a significant reason for the loss of pump head and efficiency. The penalty on pump performance is augmented by the increase in corner angle, decrease in turning radius, and installation of a short straight pipe downstream of the elbow. Pump efficiency could be maximally reduced by 6.58% with a large corner angle and a small turning radius. The bending of inlet pipes induces pressure imbalance for the two sides of the impeller and increases low-frequency disturbance in the suction chamber, which are responsible for the performance loss. Numerical results reveal that the low-frequency disturbance is caused by the vortex formed in the suction chamber, and the accompanying secondary vortex aggravates the pressure fluctuation synchronously. Parametric studies conclude that the corner angle should be minimized to reduce the penalty on pump performance and pressure fluctuations, and a long straight pipe downstream of the elbow can be installed to decrease vibration for the pump with bent inlet pipes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据