4.6 Article

Item-level psychometrics of the Ascertain Dementia Eight-Item Informant Questionnaire

期刊

PLOS ONE
卷 17, 期 7, 页码 -

出版社

PUBLIC LIBRARY SCIENCE
DOI: 10.1371/journal.pone.0270204

关键词

-

资金

  1. Ministry of Education of Republic of Korea
  2. National Research Foundation of Korea [NRF-2021S1A3A2A02096338]
  3. Institute of Convergence Science (ICONS) at Yonsei University
  4. National Research Foundation of Korea [2021S1A3A2A02096338] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

This study evaluated the item-level psychometrics of the AD-8 through confirmatory factor analysis and the Rasch rating scale model. The results showed that the AD-8 has a unidimensional measurement structure, no misfitting items, and no differential item functioning across sex and gender. Despite floor effects, the AD-8 demonstrated good reliability and can be used as a screening assessment tool in clinical settings.
The aim of this study is to evaluate the item-level psychometrics of the Ascertain Dementia Eight-Item Informant Questionnaire (AD-8) by examining its dimensionality, rating scale integrity, item fit statistics, item difficulty hierarchy, item-person match, and precision. We used confirmatory factor analysis and the Rasch rating scale model for analyzing the data extracted from the proxy versions of the 2019 and 2020 National Health and Aging Trends Study, USA. A total of 403 participants were included in the analysis. The confirmatory factor analysis with a 1-factor model using the robust weighted least squares (WLSMV) estimator indicated a unidimensional measurement structure (chi(2) = 41.015, df = 20, p = 0.004; root mean square error of approximation = 0.051; comparative fit index = 0.995; Tucker-Lewis Index = 0.993;). The findings indicated that the AD-8 has no misfitting items and no differential item functioning across sex and gender. The items were evenly distributed in the item difficulty rating (range: -2.30 to 0.98 logits). While there were floor effects, the AD-8 revealed good reliability (Rasch person reliability = 0.67, Cronbach's alpha = 0.89). The Rasch analysis reveals that the AD-8 has excellent psychometric properties that can be used as a screening assessment tool in clinical settings allowing clinicians to measure dementia both quickly and efficiently. To summarize, the AD-8 could be a useful primary screening tool to be used with additional diagnostic testing, if the patient is accompanied by a reliable informant.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据