4.6 Article

Real-time MRI motion estimation through an unsupervised k-space-driven deformable registration network (KS-RegNet)

期刊

PHYSICS IN MEDICINE AND BIOLOGY
卷 67, 期 13, 页码 -

出版社

IOP Publishing Ltd
DOI: 10.1088/1361-6560/ac762c

关键词

MR-guided radiotherapy; real-time MRI; deformable image registration; motion estimation; deep learning; U-Net

资金

  1. National Institutes of Health [R01CA240808, R01CA258987]
  2. Department of Radiation Oncology at the University of Texas Southwestern Medical Center

向作者/读者索取更多资源

KS-RegNet is an end-to-end unsupervised network that utilizes deep learning and prior information to achieve real-time 3D MR imaging and provide high-quality images for motion tracking.
Purpose. Real-time three-dimensional (3D) magnetic resonance (MR) imaging is challenging because of slow MR signal acquisition, leading to highly under-sampled k-space data. Here, we proposed a deep learning-based, k-space-driven deformable registration network (KS-RegNet) for real-time 3D MR imaging. By incorporating prior information, KS-RegNet performs a deformable image registration between a fully-sampled prior image and on-board images acquired from highly-under-sampled k-space data, to generate high-quality on-board images for real-time motion tracking. Methods. KS-RegNet is an end-to-end, unsupervised network consisting of an input data generation block, a subsequent U-Net core block, and following operations to compute data fidelity and regularization losses. The input data involved a fully-sampled, complex-valued prior image, and the k-space data of an on-board, real-time MR image (MRI). From the k-space data, under-sampled real-time MRI was reconstructed by the data generation block to input into the U-Net core. In addition, to train the U-Net core to learn the under-sampling artifacts, the k-space data of the prior image was intentionally under-sampled using the same readout trajectory as the real-time MRI, and reconstructed to serve an additional input. The U-Net core predicted a deformation vector field that deforms the prior MRI to on-board real-time MRI. To avoid adverse effects of quantifying image similarity on the artifacts-ridden images, the data fidelity loss of deformation was evaluated directly in k-space. Results. Compared with Elastix and other deep learning network architectures, KS-RegNet demonstrated better and more stable performance. The average (+/- s.d.) DICE coefficients of KS-RegNet on a cardiac dataset for the 5- , 9- , and 13-spoke k-space acquisitions were 0.884 +/- 0.025, 0.889 +/- 0.024, and 0.894 +/- 0.022, respectively; and the corresponding average (+/- s.d.) center-of-mass errors (COMEs) were 1.21 +/- 1.09, 1.29 +/- 1.22, and 1.01 +/- 0.86 mm, respectively. KS-RegNet also provided the best performance on an abdominal dataset. Conclusion. KS-RegNet allows real-time MRI generation with sub-second latency. It enables potential real-time MR-guided soft tissue tracking, tumor localization, and radiotherapy plan adaptation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据