4.6 Article

Electrochemical Immunoassay for Tumor Marker CA19-9 Detection Based on Self-Assembled Monolayer

期刊

MOLECULES
卷 27, 期 14, 页码 -

出版社

MDPI
DOI: 10.3390/molecules27144578

关键词

self-assembled membrane; gold electrode; electrochemical immunosensor; CA19-9; gastric cancer

资金

  1. National Natural Science Foundation of China [81873290]
  2. China Postdoctoral Science Foundation [2019T120626]
  3. Henan TCM Foundation [2019ZYBJ28, 20-21ZY1031, ZYZD19]
  4. Scientific and technological project of Henan Province in China [212102310366]
  5. Young and Middle-aged Academic Leaders of Health in Henan Province [2021-025]

向作者/读者索取更多资源

A CA19-9 electrochemical immunosensor was developed using a self-assembled membrane modified with a gold electrode. It demonstrated good specificity, strong anti-interference ability, and high precision and accuracy. The results showed its potential application value.
A CA19-9 electrochemical immunosensor was constructed using a hybrid self-assembled membrane modified with a gold electrode and applied to detect real samples. Hybrid self-assembled membranes were selected for electrode modification and used to detect antigens. First, the pretreated working electrodes were placed in a 3-mercaptopropionic acid (MPA)/beta-mercaptoethanol (ME) mixture for 24 h for self-assembly. The electrodes were then placed in an EDC/NHS mixture for 1 h. Layer modification was performed by stepwise dropwise addition of CA19-9 antibody, BSA, and antigen. Differential pulse voltammetry was used to characterize this immunosensor preparation process. The assembled electrochemical immunosensor enables linear detection in the concentration range of 0.05-500 U/mL of CA19-9, and the detection limit was calculated as 0.01 U/mL. The results of the specificity measurement test showed that the signal change of the interfering substance was much lower than the response value of the detected antigen, indicating that the sensor has good specificity and strong anti-interference ability. The repeatability test results showed that the relative standard deviations were less than 5%, showing good accuracy and precision. The CA19-9 electrochemical immunosensor was used for the actual sample detection, and the experimental results of the standard serum addition method showed that the RSD values of the test concentrations were all less than 10%. The recoveries were 102.4-115.0%, indicating that the assay has high precision, good accuracy, and high potential application value.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据