A shipboard method for catalytic kinetic spectrophotometric determination of trace Cu(II) concentrations in seawater using reverse flow injection analysis coupled with a long path length liquid waveguide capillary cell

期刊

MICROCHEMICAL JOURNAL
卷 179, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2022.107441

关键词

Cu(II); Catalytic kinetic method; Spectrophotometry; Reverse flow injection analysis; Liquid waveguide capillary cell; Estuarine and coastal waters

资金

  1. National Natural Science Foundation of China [41876083]

向作者/读者索取更多资源

By utilizing reverse flow injection analysis and a liquid waveguide capillary cell, a sensitive and automatic catalytic kinetic spectrophotometric method for monitoring Cu(II) concentrations in estuarine and coastal waters was established. The method showed high sensitivity and selectivity, as well as good recovery rates and reliability after optimization.
By using reverse flow injection analysis (rFIA) and a 1.0 m liquid waveguide capillary cell (LWCC), an automatic and sensitive catalytic kinetic spectrophotometric method for on-line monitoring of Cu(II) concentrations in estuarine and coastal waters was established. Cu(II) detection was based on its catalytic effect on glutathione (GSH) oxidation by potassium ferricyanide under acidic conditions. The change in absorbance of potassium ferricyanide at 420 nm was used to monitor the reaction spectrophotometrically. Experimental parameters were optimized using a univariate experimental design approach and it was ensured that the method was free of interference from co-occurring ions such as Fe(II), Fe(III), Mn, Zn, Cd, Al, Cr, Ni and Co. The proposed method was shown to have high sensitivity with a detection limit of 0.15 nmol L-1 in a pure water matrix and 0.23 nmol L-1 in a seawater matrix. Linearity was achieved within the range of 0.45-15 nmol L-1 in a pure water matrix and 0.69-10 nmol L(-1 )in a seawater matrix using a 200 cm reaction coil, while the upper limits can be extended to 40 and 25 nmol L-1, respectively, by using a shorter (100 cm) reaction coil. A high level of Cu(II) recovery was maintained, ranging between 95.2% and 101%. The relative standard deviations (RSDs) of blanks and samples spiked with 5 nmol L-1 Cu(II) standard were 1.52% (n = 13) and 1.10% (n = 13), respectively. The method was confirmed to be free of carry-over effect and a sample throughput of 26 h-1 was achieved. The method was successfully applied to underway and on-board determination of Cu(II) concentrations from a surface transect in the Jiulong Estuary and a vertical profile in the Yangtze Estuary, China, respectively.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据