4.7 Article

Fully Automated 3D Segmentation and Diffeomorphic Medial Modeling of the Left Ventricle Mitral Valve Complex in Ischemic Mitral Regurgitation

期刊

MEDICAL IMAGE ANALYSIS
卷 80, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.media.2022.102513

关键词

Diffeomorphic medial modeling; Ischemic mitral regurgitation; 3D transesophageal echocardiography; Deep learning

资金

  1. National Heart, Lung and Blood Institute of the National Institutes of Health, Bethesda, MD [R01HL10372, R01HL63954, R01HL103723, K01HL14163, F30HL142138]

向作者/读者索取更多资源

This study develops and validates a fully automated algorithm for segmentation and shape modeling of the left ventricular mitral valve complex from pre-operative 3D transesophageal echocardiography. The algorithm achieves accurate results and provides support for surgical decision making for patients with ischemic mitral regurgitation.
There is an urgent unmet need to develop a fully-automated image-based left ventricle mitral valve analysis tool to support surgical decision making for ischemic mitral regurgitation patients. This requires an automated tool for segmentation and modeling of the left ventricle and mitral valve from immediate pre-operative 3D transesophageal echocardiography. Previous works have presented methods for semiautomatically segmenting and modeling the mitral valve, but do not include the left ventricle and do not avoid self-intersection of the mitral valve leaflets during shape modeling. In this study, we develop and validate a fully automated algorithm for segmentation and shape modeling of the left ventricular mitral valve complex from pre-operative 3D transesophageal echocardiography. We performed a 3-fold nested cross validation study on two datasets from separate institutions to evaluate automated segmentations generated by nnU-net with the expert manual segmentation which yielded average overall Dice scores of 0.82 +/- 0.03 (set A), 0.87 +/- 0.08 (set B) respectively. A deformable medial template was subsequently fitted to the segmentation to generate shape models. Comparison of shape models to the manual and automatically generated segmentations resulted in an average Dice score of 0.93-0.94 and 0.75-0.81 for the left ventricle and mitral valve, respectively. This is a substantial step towards automatically analyzing the left ventricle mitral valve complex in the operating room. (C) 2022 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据