4.7 Article

Codification study of wind-induced loads on canopies attached to mid-rise buildings

出版社

ELSEVIER
DOI: 10.1016/j.jweia.2022.105050

关键词

Wind tunnel; Attached canopy; Mid-rise building; Wind load; Codes and standards

资金

  1. Florida Division of Emergency Management (DEM) [16RC-Q3-11-23-05-262]
  2. International Hurricane Research Center (IHRC) at FIU

向作者/读者索取更多资源

This study aims to investigate wind-induced loads on canopies attached to taller buildings and provide additional recommendations for the design load calculation of such non-structural attachments. Experimentation was conducted in a wind tunnel with various geometrical parameters considered. The results showed that turbulence generated by the canopy and building edges significantly affected the peak pressures on the attached canopies. Codified design curves were obtained for designing attached canopies to mid-rise buildings.
Wind-induced loads on canopies attached to low-rise buildings have been investigated in the past and formed the basis for design recommendations in the latest wind standards and building codes of practice. The scope of this study was to extend the investigation to canopies that are attached to taller buildings and generate additional recommendations on the design load calculation of such non-structural attachments. Various geometrical parameters such as canopy length, tilt angle, installation location and building height along with wind direction were considered in the experimental protocol. Therefore, several configurations of a 1:20 scale model were tested in an atmospheric boundary layer wind tunnel. Pressures on both the upper and lower surfaces of the canopy were measured for different wind directions and surface and net mean and peak pressure coefficients are presented. The results indicated that an important flow mechanism influencing the peak pressures on the attached canopies is the turbulence generated by the canopy and building edges at the wind directions parallel to the canopy's parent wall. From a codification point of view, the area-averaged coefficients versus effective area curves were obtained and enveloped, considering all model configurations, to generate design area-averaged coefficients curves. These codified design curves can be incorporated into wind standards and building codes of practice for the purpose of designing attached canopies to mid-rise buildings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据