4.5 Article

Soft tissue augmentation with a volume-stable collagen matrix or an autogenous connective tissue graft at implant sites: Five-year results of a randomized controlled trial post implant loading

期刊

JOURNAL OF PERIODONTOLOGY
卷 94, 期 2, 页码 230-243

出版社

WILEY
DOI: 10.1002/JPER.22-0226

关键词

collagen matrix; dental implants; esthetic; oral surgical procedures; tissue transplantation

向作者/读者索取更多资源

This randomized controlled trial aimed to assess the long-term clinical and radiographic outcomes of soft tissue augmentation using volume-stable collagen matrix (VCMX) or subepithelial connective tissue grafts (SCTGs) at implant sites. The study found that both VCMX and SCTG resulted in stable peri-implant tissues, favorable esthetics, and clinically negligible contour changes at 5 years post loading.
Background Interventions to augment the mucosal thickness around dental implants are indicated to optimize esthetics and maintain peri-implant health. However, there is a lack of clinical data on the long-term performance of soft tissue substitutes, such as volume-stable collagen matrix (VCMX), compared to autogenous grafts, such as subepithelial connective tissue grafts (SCTGs). This randomized controlled trial aimed to assess 5-year data on clinical and radiographic outcomes at implant sites previously augmented with VCMX or SCTG. Methods Twenty patients were randomly assigned for soft tissue augmentation with VCMX or SCTG at single implant sites. Following abutment connection, final restorations were inserted (baseline; BL) and patients were reexamined up to 5 years (FU-5). Measurements included clinical data, marginal bone levels, mucosal thickness, and ridge contour changes. Nonparametric tests and estimates were applied for the statistical analysis. Results The median buccal mucosal thickness increased by 0.3 mm (Q1: -0.8; Q3: 1.0) in the VCMX group (P = 0.656) and 0.3 mm (Q1: 0.0; Q3: 1.0) in the SCTG group (P = 0.188) between BL and FU-5 (intergroup P = 0.752), while the ridge contour decreased by a median of -0.3 mm (-0.9; -0.1) (P = 0.078) for VCMX and -0.3 mm (-0.4; -0.2) (P = 0.039) for SCTG (intergroup P = 0.817). Peri-implant health was maintained in both groups with stable clinical and radiographic outcomes and without significant differences between the treatments. Conclusion Despite the limited power and considerable dropout rate in the present study, soft tissue augmentation at implant sites with either VCMX or SCTG resulted in similar stable peri-implant tissues, favorable esthetics, and clinically negligible contour changes at 5 years post loading.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据