关键词

Optimal sensor placement; Contamination probability; Multi -objective optimization; Contamination impact

资金

  1. National Key R & D Program of China [2019YFC0408805]
  2. Key Technology Application and Demonstration of Water Conservation Society Innovation Pilot in Jinhua, Zhejiang [SF -201801]

向作者/读者索取更多资源

Contaminant intrusion in water distribution networks can jeopardize the safety of residential drinking water. Sensor placement optimization is crucial for improving the detection efficiency, as the number and location of sensors are critical factors. This study proposes a multi-objective sensor placement optimization method based on contamination risks, which takes into account the impact of contamination events and helps to identify the optimal placement scheme.
Contaminant intrusion in water distribution networks affects the safety of residential drinking water, and sensors are placed to detect a contaminant intrusion. As the number and location of sensors directly affect the detection efficiency, several studies focused on sensor placement optimization. Sensor placement optimization is an important mitigation measure, which is necessary to reduce the serious consequences of contaminant intrusion as different nodes impact differently on the water distribution networks after contaminant intrusion, that is, the risk levels of contaminant intrusion at nodes are different. Existing studies have considered changes in the probability of node contamination, but this probability is primarily based on the properties of the node itself. This study proposes a multi-objective sensor placement optimization method based on contamination risks, which involves the following steps. (1) Four different types of contamination probabilities are defined in terms of the impact of the contamination events. This is followed by solving a multi-objective optimization problem to obtain the Pareto fronts that are based on a variety of assumptions for the contamination probability distribution. (2) The Pareto fronts are ranked and clustered through a multi-criteria decision analysis, which leads to the optimal scheme in each cluster under different preferences. (3) The optimal schemes are compared in terms of the impact of the contaminant intrusion on the network. The proposed method is empirically evaluated by using the D-town network model. The results reveal that when node-to-node variation in the contamination probability is enabled, each sensor placement scheme exhibits a high true detection rate of contamination. The contamination probability based on the number of affected pipelines can yield optimal sensor placement for a fixed number of sensors to minimize the impact of contaminant intrusion on the pipeline network.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据