4.6 Article

Ultrafast simultaneous chiral analysis of native amino acid enantiomers using supercritical fluid chromatography/tandem mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1677, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2022.463305

关键词

Amino acid; Chiral separation; Ultrafast chromatography; Supercritical fluid chromatography; Mass spectrometry

资金

  1. Japan Society for the Promotion of Science (JSPS) [17H06304, 18H01800]

向作者/读者索取更多资源

In this study, a novel method combining supercritical fluid chromatography (SFC) and tandem mass spectrometry was developed for the chiral analysis of natural amino acids. By optimizing the separation column and mobile phase, successful separation and analysis of various amino acid enantiomers were achieved, significantly reducing the analysis time. The method was validated through the analysis of a commercially available product, demonstrating its practicality in amino acid analysis.
In the chiral separation of amino acids, liquid chromatography has been mainly used because of the physicochemical properties of the analytes. To date, only few reports of the use of supercritical fluid chromatography (SFC) for the analysis of chiral amino acids exist, and there is much room for improvement in terms of the number of measurable amino acids, peak shape, and analysis time. In this study, we developed a novel method for the chiral analysis of native amino acids using a system combining SFC and tandem mass spectrometry. Specifically, the separation of amino acid enantiomers was investigated using a CROWNPAK CR-I(+) column with a chiral stationary phase of optically active crown ether. Methanol/water mobile phase with trifluoroacetic acid as a modifier based on supercritical carbon dioxide (CO2) was used. At a low modifier concentration of 30% for the separation of hydrophilic compounds, 18 proteinogenic amino acid enantiomers except glycine and proline were successfully separated with resolution (Rs) = 1.96-33.62 within 6.5 min. In attempt to shorten the analysis time, the flow rate was increased; using a CO2/modifier ratio of 60/40 at a flow rate of 3 mL/min, ultrafast chromatography of 17 amino acid enantiomers, except histidine, was achieved with retention time <= 1 min and resolution >= 1.5. The developed ultrafast chiral separation method was verified by analyzing a commercially available black vinegar, which detected eight kinds of D-amino acids. The present method has thus confirmed to be successful and practical in terms of both analyte coverage and throughput. (C) 2022 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据