4.6 Article

Carotid ultrasound following transcarotid transcatheter aortic valve replacement

期刊

INTERNATIONAL JOURNAL OF CARDIOLOGY
卷 358, 期 -, 页码 12-16

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ijcard.2022.04.054

关键词

Transcarotid; TAVI; TAVR; Doppler; Ultrasound

资金

  1. Mediterranean Academic Research and Studies in Cardiology association (MARS Cardio)

向作者/读者索取更多资源

This study evaluated the safety of transcatheter aortic valve replacement (TAVR) via the transcarotid route through pre- and post-procedure carotid artery ultrasound assessment. The results showed that TC-TAVR was associated with a mild but significant increase in carotid flow velocities, without clinical events. Further studies are needed.
Background: Transcarotid (TC) is a common alternative access for transcatheter aortic valve replacement (TAVR) when the transfemoral route is not suitable. However, scarce data exist on systematic ultrasound (US) follow-up of these patients. This study aims to evaluate the safety of TC-TAVR using pre-and post-procedure carotid artery US assessment. Methods: We performed an observational prospective study including 50 consecutive patients who underwent TC-TAVR that had a follow-up at our institution between September 2016 and July 2020. Results: All patients had a carotid US examination at a median time of 13 months (IQR: 5-17) following the procedure. Thirty-six (71%) patients also had a US examination prior to the procedure. Mean pre-procedural access route common carotid artery (AR-CCA) peak systolic velocity (PSV) was 62.9 cm/s (SD:16.8) vs. 69.0 cm/s (SD: 53.4) in the contralateral CCA (CL-CCA), p = 0.562). There was a significant increase in postprocedural PSV values in the AR-CCA (30.3 cm/s (SD: 36.3), p < 0.001) but not in the CL-CCA (5.8 cm/s (SD: 51.7), p = 0.503). Two new carotid stenoses (4%) were diagnosed after the procedure. No baseline or procedural variables were associated with a higher increase in carotid flow velocities at follow-up. There were no cerebrovascular events related to these findings after a median follow-up of 29 months (IQR:13-33). Conclusions: TC-TAVR was associated with a mild but significant increase in carotid flow velocities, with new significant (>50%) carotid stenosis diagnosed in 4% of patients. These findings were not associated with clinical events after a median follow-up of 2 years. Further studies are warranted.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据