Contactless Monitoring of Heart Rate Variability During Respiratory Maneuvers

期刊

IEEE SENSORS JOURNAL
卷 22, 期 14, 页码 14563-14573

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2022.3174779

关键词

Heart rate variability; Biomedical monitoring; Task analysis; Sensors; Monitoring; Webcams; Electrocardiography; Heart rate variability; breathing rate; remote; smartphone; autonomic nervous system; optic sensors

向作者/读者索取更多资源

This study demonstrates the reliability of pulse rate variability (PRV) as a marker for cardiovascular health during different controlled breathing rates. The results show agreement between PRV and heart rate variability (HRV) measurements obtained from ECG devices, as well as consistent spectral analysis results. The findings support the use of PRV as a noninvasive method for monitoring autonomic nervous system balance.
Heart rate variability (HRV) is a noninvasive marker for the cardiovascular system and the substantial influence of this system on the autonomous nervous system (ANS). Contact and remote photoplethysmography (PPG) proved to be a reliable means of pulse rate variability (PRV) measurement as in wearable devices or imaging PPG using video cameras with evolved technical specifications. However, PRV effectiveness remains unclear during controlled breathing rate. Specifically, respiratory rate, among other physiological factors, applies profound effects on ANS balance. In this study, we demonstrated that PRV can be a reliable marker, as HRV, during various controlled breathing rates. We evaluated the proposed PRV monitoring study against reference HRV obtained from an ECG measurement device. PRV was measured from video streams captured using a smartphone and a webcam for the upper abdominal section of healthy volunteers while in standing position and performing six different respiratory maneuvers. We evaluated frequency and nonlinear HRV indices. Agreement between all indices was tested for camera-based devices and ground truth for all performed tasks. The agreement presented a consistent mean close to 95% limit of agreement (LoA). Also, we employed spectral analysis and measured the spectral divergences, normalized root mean squared error (NRMSE), and correlation. Kullback-Leibler Divergence median and percentiles results indicate congruent spectrums, where the maximum median was 0.18. A significant spectral correlation with minimum value of 0.98, and relatively low spectrum NRMSE of 0.24 were observed. Moreover, the results led to HRV physiological related phenomena which agreed with physiologically interpretations found in the literature.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据