4.7 Article

Crystalline silicon photovoltaic module degradation: Galvanic corrosion and its solution

期刊

ENGINEERING FAILURE ANALYSIS
卷 138, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.engfailanal.2022.106329

关键词

Galvanic corrosion; PERC PV modules; PV module reliability; PV module corrosion

资金

  1. Korea Electric Power Corporation [R21XO01-22]
  2. New & Renewable Energy Technology Development Program of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) [20203030010310]

向作者/读者索取更多资源

Experimental and numerical analysis showed that power reduction in silicon photovoltaic modules occurs faster in acidic environments than in pure water, with over 60% power loss in all environments after 144 hours. Particularly, a high acetic acid concentration of 20 wt% led to a rapid power loss of over 40% after just 48 hours. The corrosion of rear aluminum around the silver contact is identified as the main cause of device power losses, which can be efficiently prevented by a polymer (EPDM) without increasing production costs.
Corrosion is a significant cause of degradation of silicon photovoltaic modules. In this study, the corrosion of multicrystalline passivated emitter and rear cells (PERC) was investigated using both experimental and numerical approaches to identify high-corrosion locations and their effect on cell parameters. Corrosion environments were simulated by immersing the device in acetic acid solution at various dwell times. The impact of the acetic acid concentration and relative humidity was examined. Thermodynamic and kinetic analyses of corrosion were performed using a Pourbaix diagram and finite element analysis, respectively. The results indicate that the device power reduces slowly in pure water but is faster in acidic environments at dwell times below 96 h. The power loss was over 60% in all environments at a dwell time of 144 h. In particular, a rapid power loss over 40% was observed at a high acetic acid concentration of 20 wt% after a dwell time of merely 48 h. The power loss in the water environment can essentially occur due to the formation of a surficial metal oxide layer, while in an acidic environment, it may be due to corrosion and/or metal electrode dissolution. The simulation and experimental results demonstrate that the rear aluminum around the silver contact suffers crucially from corrosion; thus, it is the main cause of device power losses. A polymer (EPDM) efficiently prevents water penetration into the electrode areas, thus minimizing power loss due to corrosion, and effectively solves the problem without impacting the production cost.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据