4.7 Article

Heat-power decoupling and energy saving of the CHP unit with heat pump based waste heat recovery system

期刊

ENERGY
卷 250, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2022.123846

关键词

Electric heat pump (EHP); Absorption heat pump (AHP); Combined heat and power (CHP); Waste heat recovery; Heat-power decoupling; Energy saving

资金

  1. China national key research and development program-China-Finland intergovernmental coop-eration in science and technology innovation [2021YFE0116200]
  2. Academy of Finland [336268, 334205]
  3. Academy of Finland (AKA) [334205, 336268, 334205] Funding Source: Academy of Finland (AKA)

向作者/读者索取更多资源

This paper proposes using an electric heat pump to decouple heat and power and save energy, and analyzes the heat-power decoupling and energy saving potential. The results indicate that the heat-power decoupling potential is greater when the heat pump DH ratio and heat demand increase, and increasing the coefficient of performance and heat pump DH ratio can enhance the energy saving effect.
Combined heat and power (CHP) plants are operating under more fluctuating working conditions due to the increasingly inconsistent demands for heat and power and integration of renewable energy. This paper proposes to use an electric heat pump (EHP) to decouple heat and power and save energy by recovering waste heat from the cooling water. The thermodynamic model of the CHP unit under dynamic working conditions is established, and the dynamic EHP model based on an efficiency factor is proposed. The heat-power decoupling and energy -saving potential with different heat and power outputs and the heat pump DH ratio (chi(HP)) are analyzed for a CHP unit as a case study. Absorption heat pump (AHP) and EHP-based waste heat recovery systems are also compared. The results indicate that the heat-power decoupling potential is bigger when chi(HP)& nbsp;and the heat demand are increasing. The energy -saving effect is clearer by increasing the coefficient of performance (COP), chi(HP), or both. AHP and EHP can help the system obtain a certain level of heat-power decoupling and energy -saving effects, but these effects of the AHP-based system are smaller than that of EHP, especially under the working conditions of high heat demand and low power demand. (C)& nbsp;2022 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据