4.5 Article

The Effect of Microencapsulated PCM Slurry Coolant on the Efficiency of a Shell and Tube Heat Exchanger

期刊

ENERGIES
卷 15, 期 14, 页码 -

出版社

MDPI
DOI: 10.3390/en15145142

关键词

heat exchanger; microencapsulation; phase change materials; refrigerant; heat transfer coefficient

资金

  1. Polish National Science Center [2021/05/X/ST8/00023]

向作者/读者索取更多资源

This paper presents experimental results on heat transfer in a shell and tube heat exchanger during phase changes of the HFE 7000 refrigerant. The use of a mixture of water and phase change material as a coolant enhances heat exchange in the exchanger, leading to increased heat transfer coefficient and heat efficiency.
This paper describes the results of experimental studies on heat transfer in a shell and tube heat exchanger during the phase changes of the HFE 7000 refrigerant. The studies were performed using a mixture of water and a microencapsulated phase change material as a coolant. HFE 7000 refrigerant condenses on the external surface of the copper tube, while a mixture of water and phase change materials flows through the channels as coolant. Currently, there is a lack of research describing cooling using phase change materials in heat exchangers. There are a number of publications describing the heat exchange in heat exchangers during phase changes under air or water cooling. Therefore, the research hypothesis was adopted that the use of mixed water and microencapsulated material as a heat transfer fluid would increase the heat capacity and contribute to the enhancement of the heat exchange in the heat exchanger. This will enable an increase in the total heat transfer coefficient and the heat efficiency of the exchanger. Experimental studies describe the process of heat transfer intensification in the above conditions by using the phase transformation of the cooling medium melting. The test results were compared with the results of an experiment in which pure water was used as the reference liquid. The research was carried out in a wide range of refrigerant and coolant parameters: m(r) = 0.0014-0.0015 kg center dot s(-1), m(c) = 0.014-0.016 kg center dot s(,)(-1) refrigerant saturation temperature Ts = 55-60 degrees C, coolant temperature at the inlet Tc-in = 20-32 degrees C, and heat flux density q = 7000-7450 W center dot m(-1). The obtained results confirmed the research hypothesis. There was an average of a 13% increase in the coolant heat transfer coefficient, and the peak increase in alpha c was over 24%. The average value of the heat transfer coefficient k increased by 5%, and the highest increases in the value of k were noted at T-in = 27 degrees C and amounted to 9% in relation to the reference liquid.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据