4.7 Article

Testing Frequency Matters: An Evaluation of the Diagnostic Performance of a Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Rapid Antigen Test in US Correctional Facilities

期刊

CLINICAL INFECTIOUS DISEASES
卷 76, 期 3, 页码 E327-E335

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/cid/ciac450

关键词

diagnostic accuracy; COVID-19; rapid antigen test; correctional facility

向作者/读者索取更多资源

Through evaluation of the BinaxNOW rapid antigen test in different collection frequency strategies, this study provides evidence for the utility of serial rapid antigen test collection in congregate facility settings. The findings demonstrate high diagnostic accuracy of serial antigen test collection, supporting its use in outbreak investigation, screening, and situations requiring rapid detection.
Through the evaluation of the BinaxNOW rapid antigen test under varying collection frequency strategies, we provide evidence of the utility of serial rapid antigen test collection within congregate facility settings for outbreak investigation, screening, and when rapid detection is required. Background The Centers for Disease Control and Prevention recommends serial rapid antigen assay collection within congregate facilities. Although modeling and observational studies from communities and long-term care facilities have shown serial collection provides adequate sensitivity and specificity, the accuracy within correctional facilities remains unknown. Methods Using Connecticut Department of Correction data from 21 November 2020 to 15 June 2021, we estimated the accuracy of a rapid assay, BinaxNOW (Abbott), under 3 collection strategies: single test collection and serial collection of 2 and 3 tests separated by 1-4 days. The sensitivity and specificity of the first (including single), second, and third serially collected BinaxNOW tests were estimated relative to RT-PCRs collected <= 1 day of the BinaxNOW test. The accuracy metrics of the testing strategies were then estimated as the sum (sensitivity) and product (specificity) of tests in each strategy. Results Of the 13 112 residents who contributed >= 1 BinaxNOW test during the study period, 3825 contributed >= 1 RT-PCR paired BinaxNOW test. In relation to RT-PCR, the 3-rapid-antigen-test strategy had a sensitivity of 95.9% (95% CI: 93.6-97.5%) and specificity of 98.3% (95% CI: 96.7-99.1%). The sensitivities of the 2- and 1-rapid-antigen-test strategies were 88.8% and 66.8%, and the specificities were 98.5% and 99.4%, respectively. The sensitivity was higher among symptomatic residents and when RT-PCRs were collected before BinaxNOW tests. Conclusions We found serial antigen test collection resulted in high diagnostic accuracy. These findings support serial collection for outbreak investigation, screening, and when rapid detection is required (such as intakes or transfers).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据