This study found that arterial and venous blood samples have no significant differences in most coagulation parameters, except for two parameters which had very small differences that are clinically insignificant. In conclusion, both arterial and venous blood samples can be used for coagulation and fibrinolysis analysis.
Objectives No consensus exists upon whether arterial and venous blood samples are equivalent when it comes to coagulation analyses. We therefore conducted a comparative cohort study to clarify if arteriovenous differences affect analyses of primary and secondary hemostasis as well as fibrinolysis. Methods Simultaneous paired blood samplings were obtained from a cannula in the radial artery and an antecubital venipuncture in 100 patients immediately before or one day after thoracic surgery. Analyses of platelet count and aggregation, International Normalized Ratio (INR), activated partial thromboplastin time (APTT), antithrombin, thrombin time, fibrinogen, D-dimer, rotational thromboelastometry (ROTEM), thrombin generation, prothrombin fragment 1 + 2, and an in-house dynamic fibrin clot formation and lysis assay were performed. Results No differences were found between arterial and venous samples for the far majority of parameters. The only differences were found in INR, median (IQR): venous, 1.1 (0.2) vs. arterial, 1.1 (0.2) (p<0.002) and in prothrombin fragment 1 + 2: venous, 289 (209) pmol/L vs. arterial, 279 (191) pmol/L (p<0.002). Conclusions The sampling site does not affect the majority of coagulation analyses. Small differences were found for two parameters. Due to numerically very discrete differences, they are of no clinical relevance. In conclusion, the present data suggest that both samples obtained from arterial and venous blood may be applied for analyses of coagulation and fibrinolysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据