A novel point-of-care device accurately measures thyrotropin in whole blood, capillary blood and serum

期刊

CLINICAL CHEMISTRY AND LABORATORY MEDICINE
卷 60, 期 10, 页码 1607-1616

出版社

WALTER DE GRUYTER GMBH
DOI: 10.1515/cclm-2022-0525

关键词

hyperthyroidism; hypothyroidism; point-of-care testing; thyrotropin

资金

  1. Merck Healthcare KGaA, Darmstadt, Germany
  2. Wondfo Biotech Co., Guangzhou, China
  3. Merck Healthcare KGaA

向作者/读者索取更多资源

This study evaluated the analytical performance of a new point-of-care (POC) thyrotropin (TSH) assay called Wondfo. The results showed that the Wondfo system was user-friendly and demonstrated analytical performance suitable for the prompt diagnosis of thyroid dysfunction.
Objectives Point-of-care (POC) measurement of thyrotropin (TSH) may facilitate prompt diagnosis of thyroid dysfunction. We evaluated the analytical performance of a new POC TSH assay (Wondfo). Methods TSH measurements were made from 730 consecutive, unselected subjects in an outpatient setting, using Wondfo in whole blood, capillary blood and serum or automated reference equipment (serum only). Results TSH measurements were user-independent. Total intra-and inter-assay variation (CV%) was 12.1 and 16.2%, respectively. Total CV% was 10.6-22.6% and 14.5-21.6% in serum and whole blood, respectively. Linearity was very good. Recovery rate was 97-127%. Prolongation of incubation time increased TSH results of 12% (13%) and 33% (35%) after 2 and 5 additional minutes in serum (blood), respectively. When measured simultaneously in two Wondfo devices, the slope of the regression line was 1.03 (serum) and 1.02 (blood), with Spearman's correlation of 0.99 for both. TSH measurements between Wondfo and reference correlated strongly (r=0.93-0.96), though TSH measurements were lower with Wondfo (slopes of plots of measurements made using the two devices were 0.94 [serum vs. serum]; 0.83 [whole blood vs. serum] and 0.64 [capillary blood vs. serum]). Depending on sample material, TSH in capillary blood was lower vs. whole blood (slope: 0.82) and for whole blood vs. serum (Wondfo and reference method; slope: 0.69 and 0.83). Total haemolysis, but not elevated bilirubin or lipemia, disrupted TSH measurement. Conclusions The Wondfo system was straightforward to use without need for specialist technicians and demonstrated analytic performance suitable for clinical use for the diagnosis of thyroid dysfunction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据