4.7 Article

Chloride-induced corrosion of steel reinforcement in mortars manufactured with alternative environmentally-friendly binders

期刊

CEMENT & CONCRETE COMPOSITES
卷 130, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.cemconcomp.2022.104557

关键词

Corrosion; Hybrid cements; Carbon steel; Chloride diffusion; Electrochemistry

资金

  1. Ministerio de Ciencia, Innovacion y Universidades of Spain [RTI2018-096428-B-I00]
  2. Madrid Government (Comunidad de Madrid) [FRC-207160]
  3. Madrid Government (Comunidad de Madrid) under the Multiannual Agreement [FRC-207160]
  4. University of Akron, Fellowship Program [HORATSO-CS-UC3M]

向作者/读者索取更多资源

There is a growing interest in exploring the durability of structures made with environmentally friendly cements compared to traditional Portland cement. Research shows that the corrosion rate of steel embedded in AAM mortar is similar to conventional CEM IV mortars, with a less localized attack morphology.
There is increasing interest in exploring the durability of structures manufactured with cements that are more environmentally friendly than traditional Portland. Accordingly, protection against chloride-induced corrosion of carbon steel reinforcement in mortars manufactured with environmentally friendly hybrid cements and alkali-activated materials (AAM) needs to be analyzed in-depth. Hybrid cements are innovative alternative binders with reduced amount of clinker in their formulation (20-30%). Their precursors are aluminosilicate wastes and they are very feasible in-construction implantation because they are not activated neither with liquid solutions of strong alkalinity nor external heating. In this research, AAM mortars were manufactured using slag from in-dustrial by-products activated with sodium silicate. Hybrid mortars were manufactured either from fly ash or from slag, and activated with Na2SO4. Portland cement (CEM IV) mortars were also included in this study as reference. Chlorides were made to penetrate into the four different mortars under study by diffusion. The porosity and chloride penetration were evaluated and related to the different materials. The electrochemical behavior of the steel reinforced mortar specimens was monitored by open circuit potential (OCP) and electro-chemical impedance spectroscopy (EIS) measurements. The corrosion rate values obtained for steel embedded in AAM were similar to conventional CEM IV mortars, and the morphology of the attack is less localized.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据