4.6 Article

Asymptomatic COVID-19 CT image denoising method based on wavelet transform combined with improved PSO

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.bspc.2022.103707

关键词

Wavelet transform; Asymptomatic COVID-19; Threshold function; Particle swarm optimization (PSO); Gaussian noise

资金

  1. National Key R&D Program of China [2017YFF0207400]
  2. Beijing Municipal Science and Technology Commission-Beijing Natural Science Foundation [M21018]
  3. Beijing Natural Science Foundation-haidian District Joint Fund for original innovation [L192064]

向作者/读者索取更多资源

This paper proposes a denoising method based on wavelet transform with a shrinkage factor, which can effectively address the issue of noise interference in asymptomatic COVID-19 CT images. By optimizing the parameters and combining with an improved particle swarm optimization algorithm, the parameters of the wavelet threshold function can be adaptively adjusted to further improve the denoising effect.
The quality of asymptomatic corona virus disease 2019 (COVID-19) computed tomography (CT) image is reduced due to interference from Gaussian noise, which affects the subsequent image processing. Aiming at the problem that asymptomatic COVID-19 CT image often have small flake ground-glass shadow in the early lesions, and the density is low, which is easily confused with noise. A denoising method of wavelet transform with shrinkage factor is proposed. The threshold decreases with the increase of decomposition scale, and it reduces the misjudgment of signal points. In the advanced stage, the range of lesions increases, with consolidation and fibrosis in different sizes, which have similar gray value to the CT images of suspected cases. Aiming at the problems of low contrast and fuzzy boundary in the traditional wavelet transform, the threshold function based on the optimization of parameters combined with the improved particle swam optimization (PSO) is proposed, so that the parameters of wavelet threshold function can change adaptively according to the lung lobe and groundglass lesions with fewer iterations. The simulation results show that the paper method is significantly better than other algorithms in peak signal-to-noise ratio (PSNR), signal-to-noise ratio (SNR) and mean absolute error (MSE). For example, aiming at the early asymptomatic COVID-19, compared with the comparison methods, the PSNR under the proposed method has increased by about 5 dB, the MSE has been greatly reduced, and the SNR has increased by about 6.1 dB. It can be seen that the denoising effect under the proposed method is the best.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据