期刊
ANALYTICA CHIMICA ACTA
卷 1221, 期 -, 页码 -出版社
ELSEVIER
DOI: 10.1016/j.aca.2022.340117
关键词
Magneticsorbent; Bioanalysis; Dispersive-basedmicroextraction; Pipettetip-basedmicroextraction; Salivasample; Testosterone
资金
- Spanish Ministry of Science and Innovation (MCIN/AEI) [PID2020-118924RB-I00]
- Spanish Ministry of Science, Innovation and Universities [RED -2018-102522-T]
- Division of Analytical Chemistry of the European Chemical Society
A novel high-throughput pipette tip microextraction strategy using a magnetic sorbent has been developed, offering satisfactory results with minimal number of aspirating/dispensing cycles, benefiting the ergonomics for the operator. The strategy has been successfully tested for measuring testosterone levels in saliva of volunteers, achieving low limits of detection and quantification, good repeatability, and high relative recoveries. It shows promise for rapid sample analysis and could be further improved with the use of a multichannel pipette.
In this work, a lab-made and affordable high-throughput pipette tip microextraction strategy is presented. In this approach, a magnetic sorbent is quickly dispersed in the sample by means of a disperser solvent and the resulting dispersion is immediately aspirated into a pipette tip containing a small neodymium magnet inside, which en-traps the magnetic sorbent containing the analytes. The sample is then discarded, and the subsequent cleaning and desorption steps are conducted by aspirating/dispensing the suitable solvents. This methodology provides satisfactory results when compared with previous pipette tip extraction strategies (i.e., pipette-tip solid-phase extraction and dispersive pipette extraction). Furthermore, it requires a minimum number of aspirating/ dispensing cycles, thus benefiting the ergonomics for the operator, and it is not commercially dependent. This new approach has been tested by measuring testosterone levels in saliva of volunteers as a proof-of-concept. In this regard, a magnetic composite made of CoFe2O4 magnetic nanoparticles embedded in octadecyl bonded silica microparticles was employed as sorbent material. Testosterone was quantified by liquid chromatography coupled to tandem mass spectrometry. Under the optimized conditions, low limits of detection and quantification (7.5 ng L-1 and 24.8 ng L-1, respectively), good repeatability (RSD < 9%) and relative recoveries between 82 and 106% were obtained with just one adsorption and two desorption cycles, which requires few seconds per sample. In order to increase even more the sample throughput, a multichannel pipette was also evaluated.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据