4.7 Article

Magnetic restricted-access carbon nanotubes for SPME to determine cannabinoids in plasma samples by UHPLC-MS/MS

期刊

ANALYTICA CHIMICA ACTA
卷 1226, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2022.340160

关键词

Magnetic restricted-access carbon nanotubes; Solid-phase microextraction; Cannabinoids; LC-MS/MS; Magnetic coating

资金

  1. Fundacao de Amparo `a Pesquisa do Estado de Minas Gerais (FAPEMIG, Belo Horizonte, Brazil) [CDS-APQ-00638-17]
  2. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq, Brasilia, Brazil) [301564/2019-1, 427365/2018-0]
  3. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)

向作者/读者索取更多资源

This manuscript describes the development of magnetic restricted-access carbon nanotubes as a sorbent for determining CBD and THC in human plasma samples. The method showed adequate selectivity, linearity, precision, and accuracy. It was successfully applied to determine CBD levels in healthy volunteers and THC levels in cannabis smokers.
This manuscript describes the development of magnetic restricted-access carbon nanotubes (M-RACNTs) for use as SPME sorbent to determine cannabidiol (CBD) and delta-9-tetrahydrocannabinol (THC) in human plasma samples by UHPLC-MS/MS. The adsorptive phase was immobilized on an SPME device by electromagnetic interactions between the M-RACNTs and a cylindrical neodymium magnet (3-mm diameter x 8-mm height) attached to a stainless-steel rod (3-mm diameter x 40-mm height). The M-RACNTs were synthesized by incorporating Fe3O4 magnetic nanoparticles (MNPs) into commercial carbon nanotubes (CNTs); then the surface of the resulting sorbent was further coated with a layer of bovine serum albumin (BSA). Characterization techniques (SEM, FTIR, and Zeta potential) confirmed the presence of both MNPs and BSA layer dispersed through the structure of the CNTs. The M-RACNTs presented adequate sorption capacity, stable physical/chemical characteristics, and appropriate magnetic properties. Protein exclusion capacity (about 98.5%) was attributed to the chemical diffusion barrier created by the BSA network at the outer surface of the sorbent. The SPME parameters (sample pH, equilibrium time, and desorption conditions) were optimized by design of experiments (fraction factorial planning). The method (validated according to the FDA guidelines) presented adequate selectivity and linearity (coefficient of determination higher than 0.99) at concentrations ranging from the lower limit of quantification (LLOQ) (10 ng mL(-1)) to the upper limit of quantification (ULOQ) (300 ng mL(-1)) for both CBD and THC. Precision and accuracy varied from 4.47 to 19.84% (LLOQ) and -6.90 to 17.78% (LLOQ), respectively. Carry-over and matrix effect were not significant. The method was successfully applied to determine plasmatic CBD levels in healthy volunteers attending a single session of oral drug administration and THC levels in frequent cannabis smokers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据