4.6 Article

A pacing-controlled protocol for frequency-diastolic relations distinguishes diastolic dysfunction specific to a mouse HFpEF model

出版社

AMER PHYSIOLOGICAL SOC
DOI: 10.1152/ajpheart.00241.2022

关键词

-

资金

  1. Fukuda Foundation for Medical Technology
  2. JSPS KAKENHI Scientific Research [21K08047]

向作者/读者索取更多资源

HFpEF is a global health issue with a lack of stable methods for detecting diastolic dysfunction in mouse models. The authors developed a pacing-controlled protocol to evaluate diastolic function at different heart rates in mice and successfully detected diastolic dysfunction specific to an HFpEF model.
Heart failure with preserved ejection fraction (HFpEF), characterized by diastolic dysfunction and insufficient exercise capacity, is a growing health problem worldwide. One major difficulty with experimental research on HFpEF is the lack of methods to consistently detect diastolic dysfunction in mouse models. We developed a pacing-controlled pressure-volume (PV) loop protocol for the assessment of diastolic function at different heart rates in mice and tested if the protocol could detect diastolic dysfunction specific to a HFpEF model. A HFpEF model was generated by high-fat diet (HFD) feeding with concomitant NG-nitro-L-arginine methyl ester administration, and a pressure-overload hypertrophy (PO) model was produced by surgical constriction of the transverse aorta (TAC). Heart rate (HR) was slowed below 400 beats/min by intraperitoneal injection of ivabradine. PV loop data were acquired and analyzed at HR incrementing from 400 to 700 beats/min via atrial pacing using a miniature pacing catheter inserted into the esophagus, and comparisons were made among control, HFpEF, and PO mice. At baseline without pacing, no diastolic abnormalities were detected in either PO or HFpEF models. Frequency-diastolic relations, however, revealed the significant diastolic impairment specific to the HFpEF model; both relaxation time constant (Tau) and end-diastolic pressure-volume relationship (EDPVR) were worsened as heart rate increased. Peak positive first derivative of left ventricular pressure (dP/dtmax) was significantly lower in HFpEF versus controls only at a high HR of 700 beats/min. A pacing-controlled protocol would be a feasible and potent method to detect diastolic dysfunction specific to a mouse HFpEF model. NEW & NOTEWORTHY We developed a pacing-controlled PV loop protocol for the assessment of diastolic function at different heart rates in mice, which is a feasible and potent method for the characterization of diastolic dysfunction in a murine HFpEF model whose diastolic dysfunction might be difficult to be detected under resting conditions without pacing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据