3.8 Article

Investigating the inaccuracies of indirect method of blood pressure measurement associated to the cuff constructing fabrics

出版社

MEHRAN UNIV ENGINEERING & TECHNOLOGY
DOI: 10.22581/muet1982.2202.12

关键词

Blood pressure measurement; BP monitoring; Cuff constructing fabric; Bare metal cylinder; Pressure sensing

资金

  1. NED University of Engineering and Technology, Karachi, Pakistan
  2. Higher Education Commission of Pakistan

向作者/读者索取更多资源

This study investigated the pressure distribution under different types of cuffs and found non-uniform pressure distribution at the interface among the cuffs. The pressure at the interface was lower than inside the cuffs, showing pressure attenuation as it transferred to the surface underneath. The study concludes that selecting fabric with optimized properties is crucial for accurate blood pressure estimation.
Numerous cuffs have been manufactured using different materials in which textile fabric is the main constituent. There are no specific guidelines for the selection of the cuff fabric and its design. In this investigation, five different types of cuffs (made of woven and non-woven fabrics) were selected, and their pressure distribution was noted while mimicking the process of blood pressure measurement. It was achieved by measuring pressure at the interface of the selected cuffs and a bare metal cylinder. I-scan, an interface pressure measurement system was employed to record the interface pressure profiles under the cuffs against 140 mmHg to 40 mmHg pressure inside the cuffs. The data obtained from the pressure sensing system was processed in MATLAB to examine pressure distribution at 96 points in detail. The results show that the cuffs registered non-uniform pressure distribution at the interface which is also non-identical among the selected cuffs. The pressure at the interface is found to be lower than the pressure inside the cuff, which shows that pressure attenuates as transfers to the surface of the object underneath it. The range of the pressure difference varies from 10 mmHg to 15 mmHg. This study indicates that the pressure distribution under a cuff depends on the constructing fabric and its properties. It is concluded that there is a need to select appropriate fabric with optimized properties for desired pressure distribution which may lead to accurate estimation of blood pressure.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据