4.6 Article

A rapid method for the separation of vitamin D and its metabolites by ultra-high performance supercritical fluid chromatography-mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1440, 期 -, 页码 191-200

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2016.02.043

关键词

Ultra-high performance supercritical fluid chromatography; Vitamin D-2 and D-3 metabolites; Orthogonal column screening; Method development; Plasma; Mass spectrometry

资金

  1. Bokelunds resestipendiefond [94507]
  2. Swedish Research Council FORMAS [229-2009-1527]
  3. Swedish Research Council [2010-333, 112 84]
  4. Kurdistan Regional Government-Human Capacity Development Program (KRG-HCDP)

向作者/读者索取更多资源

In this study, a new supercritical fluid chromatography-mass spectrometry (SFC-MS) method has been developed for the separation of nine vitamin D metabolites within less than eight minutes. This is the first study of analysis of vitamin D and its metabolites carried out by SFC-MS. Six columns of orthogonal selectivity were examined, and the best separation was obtained by using a 1-aminoanthracene (1-AA) column. The number and the position of hydroxyl groups in the structure of the studied compounds as well as the number of unsaturated bonds determine the physiochemical properties and, thus the separation of vitamin D metabolites that is achieved on this column. All D-2 and the D-3 forms were baseline separated with resolution values >1.5. The effects of pressure, temperature, flow rate and different gradient modes were studied. Electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI(+)) were compared in positive mode, both by direct infusion and after SFC separation. The results showed that the sensitivity in APCI(+) was higher than in ESI+ using direct infusion. In contrast, the sensitivity in APCI(+) was 6-fold lower than in ESI+ after SFC separation. The SFC-MS method was validated between 10 and 500 ng/mL for all analytes with coefficient of determination (R-2) >= 0.999 for all calibration curves. The limits of detection (LOD) were found to range between 0.39 and 5.98 ng/mL for 24,25-dihydroxyvitamin D-3 (24,25(OH)(2)D-3) and 1-hydroxyvitamin D-2 (1OHD(2)), respectively. To show its potential, the method was applied to human plasma samples from healthy individuals. Vitamin D3 (D-3), 25-hydroxyvitamin D-3 (25OHD(3)) and 24,25(OH)(2)D-3 were determined in plasma samples and the concentrations were 6.6 +/- 3.0 ng/mL, 23.8 +/- 9.2 ng/mL and 5.4 +/- 2.7 ng/mL, respectively. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据