4.5 Article

Effects of Different Draw Solutions on Biogas Slurry Concentration in Forward Osmosis Membrane: Performance and Membrane Fouling

期刊

MEMBRANES
卷 12, 期 5, 页码 -

出版社

MDPI
DOI: 10.3390/membranes12050476

关键词

forward osmosis membrane; biogas slurry; draw solution; membrane fouling

资金

  1. Science and Technology Plan Project Foundation of Guizhou province [20191452]

向作者/读者索取更多资源

This study explores the application of forward osmosis (FO) membrane technology in the concentration of biogas slurry and evaluates the performance of FO membranes using three different draw solutions. The results indicate that MgCl2 is the most effective draw solution for the concentration of biogas slurry, but it is ineffective at retaining nitrogen. Furthermore, membrane fouling is primarily caused by organic fouling. This study provides a technical reference for the high-value utilization of biogas slurry.
Biogas slurry poses a severe challenge to the sustainable management of livestock farms. The technology of the forward osmosis (FO) membrane has a good application prospect in the field of biogas slurry concentration. Further research is needed to verify the effects of different draw solutions on FO membranes in biogas slurry treatment and the related membrane fouling characteristics. In this study, three different draw solutions were selected to evaluate the performance of FO membranes for biogas slurry concentration. Membrane fouling was investigated by characterization after FO membrane treatment to identify fouling contaminants. The result showed that FO membrane treatment can realize the concentration of biogas slurry and MgCl2 as the draw solution has the best effect on the concentration of biogas slurry. The different draw solutions all contributed to the efficient retention of most organics and TP while each treatment was ineffective at retaining nitrogen. The cake layer that appeared after the biogas slurry was concentrated covered the surface of the FO membrane. Some functional groups were detected on the surface after membrane fouling, such as C-O and C=C. Moreover, the C element accounts for 57% of the main components of the cake layer after the membrane fouling. Membrane fouling is caused by both organic fouling and inorganic fouling, of which organic fouling is the main reason. This study provides a technical reference for the high-value utilization of biogas slurry.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据