4.7 Article

A Single Wavelength Mid-Infrared Photoacoustic Spectroscopy for Noninvasive Glucose Detection Using Machine Learning

期刊

BIOSENSORS-BASEL
卷 12, 期 3, 页码 -

出版社

MDPI
DOI: 10.3390/bios12030166

关键词

noninvasive glucose detection; photoacoustic spectroscopy; mid-infrared spectroscopy; machine learning

资金

  1. Natural Science and Engineering Research Council (NSERC)
  2. Ontario Centre of Excellence (OCE)
  3. Mitacs
  4. University of Waterloo
  5. AIH Technologies Inc.

向作者/读者索取更多资源

Diabetes is a global issue, and the development of noninvasive monitors is crucial for diabetes management. Optical spectroscopy, particularly using a single wavelength quantum cascade laser, has shown high accuracy and sensitivity in glucose monitoring. The integration of machine learning techniques has further improved the accuracy of glucose detection.
According to the International Diabetes Federation, 530 million people worldwide have diabetes, with more than 6.7 million reported deaths in 2021. Monitoring blood glucose levels is essential for individuals with diabetes, and developing noninvasive monitors has been a longstanding aspiration in diabetes management. The ideal method for monitoring diabetes is to obtain the glucose concentration level with a fast, accurate, and pain-free measurement that does not require blood drawing or a surgical operation. Multiple noninvasive glucose detection techniques have been developed, including bio-impedance spectroscopy, electromagnetic sensing, and metabolic heat conformation. Nevertheless, reliability and consistency challenges were reported for these methods due to ambient temperature and environmental condition sensitivity. Among all the noninvasive glucose detection techniques, optical spectroscopy has rapidly advanced. A photoacoustic system has been developed using a single wavelength quantum cascade laser, lasing at a glucose fingerprint of 1080 cm(-1) for noninvasive glucose monitoring. The system has been examined using artificial skin phantoms, covering the normal and hyperglycemia blood glucose ranges. The detection sensitivity of the system has been improved to +/- 25 mg/dL using a single wavelength for the entire range of blood glucose. Machine learning has been employed to detect glucose levels using photoacoustic spectroscopy in skin samples. Ensemble machine learning models have been developed to measure glucose concentration using classification techniques. The model has achieved a 90.4% prediction accuracy with 100% of the predicted data located in zones A and B of Clarke's error grid analysis. This finding fulfills the US Food and Drug Administration requirements for glucose monitors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据