4.5 Article

The Listening Zone of Human Electrocorticographic Field Potential Recordings

期刊

ENEURO
卷 9, 期 2, 页码 -

出版社

SOC NEUROSCIENCE
DOI: 10.1523/ENEURO.0492-21.2022

关键词

electrocorticography; human; intracranial recording; inverse modeling; referencing

资金

  1. National Institutes of Health (NIH) [U01 N5098981]
  2. NIH/National Institute on Deafness and Other Communication Disorders [DC014589]
  3. University of Texas System funding for the Texas Institute for Restorative Neurotechnologies

向作者/读者索取更多资源

Intracranial electroencephalographic (icEEG) recordings provide valuable insights into neural dynamics in humans. The study quantified the listening zone of icEEG recordings and explored the influence of array design, spectral bands, and referencing schema on local field potential recordings and source localization.
Intracranial electroencephalographic (icEEG) recordings provide invaluable insights into neural dynamics in humans because of their unmatched spatiotemporal resolution. Yet, such recordings reflect the combined activity of multiple underlying generators, confounding the ability to resolve spatially distinct neural sources. To empirically quantify the listening zone of icEEG recordings, we computed correlations between signals as a function of distance (full width at half maximum; FWHM) between 8752 recording sites in 71 patients (33 female) implanted with either subdural electrodes (SDEs), stereo-encephalography electrodes (sEEG), or high-density sEEG electrodes. As expected, for both SDEs and sEEGs, higher frequency signals exhibited a sharper fall off relative to lower frequency signals. For broadband high gamma (BHG) activity, the mean FWHM of SDEs (6.6 +/- 2.5 mm) and sEEGs in gray matter (7.14 +/- 1.7 mm) was not significantly different; however, FWHM for low frequencies recorded by sEEGs was 2.45 mm smaller than SDEs. White matter sEEGs showed much lower power for frequencies 17-200 Hz (q < 0.01) and a much broader decay (11.3 +/- 3.2 mm) than gray matter electrodes (7.14 +/- 1.7 mm). The use of a bipolar referencing scheme significantly lowered FWHM for sEEGs, relative to a white matter reference or a common average reference (CAR). These results outline the influence of array design, spectral bands, and referencing schema on local field potential recordings and source localization in icEEG recordings in humans. The metrics we derive have immediate relevance to the analysis and interpretation of both cognitive and epileptic data.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据