4.6 Article

Electrocardiographic and Echocardiographic Predictors of Atrial Fibrillation in Patients With Hypertrophic Cardiomyopathy

期刊

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fcvm.2022.905128

关键词

hypertrophic cardiomyopathy; atrial fibrillation; echocardiography; electrocardiography; prognosis

向作者/读者索取更多资源

This study found that atrial fibrillation (AF) is associated with electrocardiographic and echocardiographic parameters (structural and functional) in patients with hypertrophic cardiomyopathy (HCM). Specifically, left atrium booster pump function and electrical dispersion were identified as independent predictors of AF in HCM patients, providing further assessment of AF risk in patients, including those considered at lower risk based on conventional assessment of left atrial size.
BackgroundPatients with hypertrophic cardiomyopathy (HCM) have an increased prevalence of atrial fibrillation (AF) compared to the general population, and left atrium (LA) remodeling is strongly correlated with the risk of AF. This prospective, monocentric study aimed to assess the role of LA electrocardiographic and echocardiographic (structural and functional) parameters in predicting the risk for incident AF in patients with HCM. Methods and ResultsThe study population consisted of 126 HCM patients in sinus rhythm (52.6 +/- 16.2 years, 54 men), 118 of them without documented AF. During a median follow-up of 56 (7-124) months, 39 (30.9%) developed a new episode of AF. Multivariable analysis showed that LA booster pump function (assessed by ASr, HR = 4.24, CI = 1.84-9.75, and p = 0.038) and electrical dispersion (assessed by P wave dispersion - Pd, HR = 1.044, CI = 1.029-1.058, and p = 0.001), and not structural parameters (LA diameter, LA volume) were independent predictors of incident AF. Seventy-two patients had a LA diameter < 45 mm, and 16 of them (22.2%) had an AF episode during follow-up. In this subgroup, only Pd emerged as an independent predictor for incident AF (HR = 1.105, CI = 1.059-1.154, and p = 0.002), with good accuracy (AUC = 0.89). ConclusionLeft atrium booster pump function (ASr) and electrical dispersion (Pd) are related to the risk of incident AF in HCM patients. These parameters can provide further stratification of the risk for AF in this setting, including in patients considered at lower risk for AF based on the conventional assessment of LA size.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据