4.7 Article

Dose Variations Using an X-Ray Cabinet to Establish in vitro Dose-Response Curves for Biological Dosimetry Assays

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Biology

The future of biological dosimetry in mass casualty radiation emergency response, personalized radiation risk estimation and space radiation protection

Elizabeth A. Ainsbury et al.

Summary: Ionizing radiation biodosimetry is an exciting field that will benefit from active networking and collaboration with broader fields of radiation research and emergency response. The field will continue to develop to ensure effective, coordinated approaches including emergency dosimetry, radiation epidemiology, personalized medical dosimetry, and space travel.

INTERNATIONAL JOURNAL OF RADIATION BIOLOGY (2022)

Article Oncology

High-throughput meta-analysis and validation of differentially expressed genes as potential biomarkers of ionizing radiation-response

Vanesa Biolatti et al.

Summary: The study identified potential predictive biomarkers for biodosimetry and radioinduced-response through high-throughput gene expression analysis in IR-exposed human peripheral white blood cells. Six selected DEGs were validated by qRT-PCR, showing significant upregulation post IR-exposure, with PCNA expression levels increasing dose-dependently. Notably, TCF4 was bioinformatically detected as an overrepresented TF in the radioinduced DEGs set and was validated as an IR-responsive gene post-irradiation.

RADIOTHERAPY AND ONCOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Radiation field and dose inhomogeneities using an X-ray cabinet in radiation biology research

Martin Bucher et al.

Summary: X-ray cabinets are user-friendly for biological radiation research, but field inhomogeneities and experimental setup components can significantly affect the delivered irradiation doses. Strict dosimetric monitoring is necessary for reliable studies.

MEDICAL PHYSICS (2021)

Article Multidisciplinary Sciences

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

Morgane Dos Santos et al.

Summary: The proposal suggests a dosimetry protocol for cell irradiations using low energy X-ray facility, aiming to estimate doses as close to real conditions as possible. It includes steps such as determining irradiation parameters, beam quality index, dose rate measurement, attenuation and scattering quantification, and dose rate determination at the cellular level. The methodology needs to be performed for each new cell irradiation configuration due to the potential impact of modifying parameters on the actual dose deposition.

JOVE-JOURNAL OF VISUALIZED EXPERIMENTS (2021)

Article Multidisciplinary Sciences

Inter-laboratory comparison of gene expression biodosimetry for protracted radiation exposures as part of the RENEB and EURADOS WG10 2019 exercise

M. Abend et al.

Summary: Studying gene expression changes in blood samples exposed to radiation allows for estimation of absorbed radiation doses. The impact of radiation exposure depends on factors such as time and temperature, with 37 degrees Celsius being a key temperature for biological response.

SCIENTIFIC REPORTS (2021)

Review Environmental Sciences

Early-response multiple-parameter biodosimetry and dosimetry: risk predictions

William F. Blakely et al.

Summary: A comprehensive approach for suspected high-dose radiation exposure includes various assessments such as measuring radioactivity, observing symptoms, conducting blood tests, and chromosome-aberration cytogenetic bioassays. This integrated approach is essential for early diagnostic guidance and definitive assessment of radiation dose and injury severity.

JOURNAL OF RADIOLOGICAL PROTECTION (2021)

Article Biology

CytoRADx: A High-Throughput, Standardized Biodosimetry Diagnostic System Based on the Cytokinesis-Block Micronucleus Assay

Chris Capaccio et al.

Summary: The research team has made significant advancements in radiation biodosimetry by developing the CytoRADx System, which allows for accurate diagnoses across diverse populations in large-scale emergency scenarios. The system provides high-throughput, standardized results without specialized labor or laboratory-specific calibration curves.

RADIATION RESEARCH (2021)

Article Biology

Feasibility Study on Automatic Interpretation of Radiation Dose Using Deep Learning Technique for Dicentric Chromosome Assay

Seungsoo Jang et al.

Summary: This study proposed an automated dose estimation system based on deep learning methods, achieving high accuracy. The system consists of three stages: filtering images using a classifier, evaluating dicentric rate with Feature Pyramid Network, and conducting dose estimation with the dicentric rate and dose-response curve. The system showed highest accuracy in estimating absorbed doses within a 99% confidential interval compared to previous studies.

RADIATION RESEARCH (2021)

Article Biology

Estimating partial-body ionizing radiation exposure by automated cytogenetic biodosimetry

Ben C. Shirley et al.

INTERNATIONAL JOURNAL OF RADIATION BIOLOGY (2020)

Article Multidisciplinary Sciences

Candidate protein markers for radiation biodosimetry in the hematopoietically humanized mouse model

Younghyun Lee et al.

SCIENTIFIC REPORTS (2018)

Article Environmental Sciences

BIODOSIMETRY AND BIODOSIMETRY NETWORKS FOR MANAGING RADIATION EMERGENCY

U. Kulka et al.

RADIATION PROTECTION DOSIMETRY (2018)

Article Biology

The RENEB operational basis: complement of established biodosimetric assays

Andrzej Wojcik et al.

INTERNATIONAL JOURNAL OF RADIATION BIOLOGY (2017)

Article Biology

Investigation of the influence of calibration practices on cytogenetic laboratory performance for dose estimation

Francois Trompier et al.

INTERNATIONAL JOURNAL OF RADIATION BIOLOGY (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Underestimation of dose delivery in preclinical irradiation due to scattering conditions

C. Nobler et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2014)

Review Biology

Overview of the principles and practice of biodosimetry

Harold M. Swartz et al.

RADIATION AND ENVIRONMENTAL BIOPHYSICS (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

An Investigation on the Non-uniform Distribution of Radiation Intensity Output of Diagnostic X-ray Tubes

Charles Tai Po Chan et al.

JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES (2014)

Article Biotechnology & Applied Microbiology

Automatic scoring of dicentric chromosomes as a tool in large scale radiation accidents

H. Romm et al.

MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS (2013)

Article Instruments & Instrumentation

The Importance of Dosimetry Standardization in Radiobiology

Marc Desrosiers et al.

JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (2013)

Article Multidisciplinary Sciences

Gamma-H2AX-Based Dose Estimation for Whole and Partial Body Radiation Exposure

Simon Horn et al.

PLOS ONE (2011)

Article Nuclear Science & Technology

Candidate protein biomarkers as rapid indicators of radiation exposure

Simon Horn et al.

RADIATION MEASUREMENTS (2011)

Article Engineering, Biomedical

SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes

G. Poludniowski et al.

PHYSICS IN MEDICINE AND BIOLOGY (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Calculation of x-ray spectra emerging from an x-ray tube. Part I. Electron penetration characteristics in x-ray targets

Gavin G. Poludniowski et al.

MEDICAL PHYSICS (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

Calculation of x-ray spectra emerging from an x-ray tube. Part II. X-ray production and filtration in x-ray targets

Gavin G. Poludniowski

MEDICAL PHYSICS (2007)

Review Biology

Candidate protein biodosimeters of human exposure to ionizing radiation

Francesco Marchetti et al.

INTERNATIONAL JOURNAL OF RADIATION BIOLOGY (2006)

Article Biology

Protocol for X-ray dosimetry in radiobiology

J Zoetelief et al.

INTERNATIONAL JOURNAL OF RADIATION BIOLOGY (2001)

Article Radiology, Nuclear Medicine & Medical Imaging

AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology

CM Ma et al.

MEDICAL PHYSICS (2001)

Article Chemistry, Physical

Advancements in accuracy of the alanine dosimetry system. Part 1. The effects of environmental humidity

OF Sleptchonok et al.

RADIATION PHYSICS AND CHEMISTRY (2000)