4.7 Article

Analysis and assessment of factors affecting air inflow from areas adjacent to operating rooms due to door opening and closing

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Construction & Building Technology

Impact of door opening on the risk of surgical site infections in an operating room with mixing ventilation

Cong Wang et al.

Summary: Operating rooms often have door openings connected to uncontrolled areas that are more contaminated, and opening the door may lead to an inflow of contaminated air, degrading air cleanliness and increasing the risk of surgical site infections. Numerical study showed that a single door opening could increase overall contamination in the OR by 2.1 CFU/m(3), with different contamination levels at the surgical site. Temporarily reducing OR exhaust flow during door operation was found to effectively minimize the impact of door openings on infection risk.

INDOOR AND BUILT ENVIRONMENT (2021)

Article Construction & Building Technology

Three-dimensional analysis of the effect of human movement on indoor airflow patterns

Arup Bhattacharya et al.

Summary: Human activity has significant effects on indoor airflow patterns, especially in cleanrooms, pharmaceutical settings, and healthcare environments. Experiments showed that walking can impact airflow for up to 10 seconds, with straight line walking causing significant changes in velocity. Similar airflow patterns between different walking schemes suggest the potential for predicting flow patterns of random walks.

INDOOR AIR (2021)

Review Surgery

The possible effect of different types of ventilation on reducing operation theatre infections: a meta- analysis

Q. Lv et al.

Summary: This meta-analysis found no significant difference in the risk of surgical site infection between surgery performed under laminar airflow ventilation and conventional ventilation in total hip replacement, total knee arthroplasties, and different abdominal and open vascular surgery. The type of theatre ventilation may have no influence on the occurrence of surgical site infection.

ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND (2021)

Review Construction & Building Technology

A systematic review of operating room ventilation

Sasan Sadrizadeh et al.

Summary: Ventilation systems in operating rooms are essential for eliminating airborne pathogens, but their design can be complex due to various factors. This review article highlights the challenges and controversies in designing ventilation systems for operating rooms and aims to provide a comprehensive understanding for future research and implementation.

JOURNAL OF BUILDING ENGINEERING (2021)

Article Public, Environmental & Occupational Health

Risk factors for surgical site infections in abdominal surgeries in Ghana: emphasis on the impact of operating rooms door openings

A. A. A. Bediako-Bowan et al.

EPIDEMIOLOGY AND INFECTION (2020)

Article Public, Environmental & Occupational Health

Airborne particle dispersion to an operating room environment during sliding and hinged door opening

Sasan Sadrizadeh et al.

JOURNAL OF INFECTION AND PUBLIC HEALTH (2018)

Article Construction & Building Technology

Influence of opening and closing process of sliding door on interface airflow characteristic in operating room

Bin Zhou et al.

BUILDING AND ENVIRONMENT (2018)

Article Construction & Building Technology

An observational study of door motion in operating rooms

Ehsan S. Mousavi et al.

BUILDING AND ENVIRONMENT (2018)

Review Infectious Diseases

Effect of laminar airflow ventilation on surgical site infections: a systematic review and meta-analysis

Peter Bischoff et al.

LANCET INFECTIOUS DISEASES (2017)

Article Anesthesiology

Control of the Environment in the Operating Room

Jonathan D. Katz

ANESTHESIA AND ANALGESIA (2017)

Article Construction & Building Technology

Numerical evaluation of influence of door opening on interzonal air exchange

Sihwan Lee et al.

BUILDING AND ENVIRONMENT (2016)

Article Construction & Building Technology

Control room contaminant inleakage produced by door opening and closing: Dynamic simulation and experiments

Le Chang et al.

BUILDING AND ENVIRONMENT (2016)

Article Clinical Neurology

The Barrow Randomized Operating Room Traffic (BRITE) Trial

Michael A. Bohl et al.

NEUROSURGERY (2016)

Article Thermodynamics

Airflow patterns due to door motion and pressurization in hospital isolation rooms

Ehsan S. Mousavi et al.

SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT (2016)

Article Construction & Building Technology

Potential airborne transmission between two isolation cubicles through a shared anteroom

Jian Hang et al.

BUILDING AND ENVIRONMENT (2015)

Article Construction & Building Technology

The influence of human walking on the flow and airborne transmission in a six-bed isolation room: Tracer gas simulation

Jian Hang et al.

BUILDING AND ENVIRONMENT (2014)

Article Orthopedics

The Effect of Laminar Air Flow and Door Openings on Operating Room Contamination

Eric B. Smith et al.

JOURNAL OF ARTHROPLASTY (2013)

Article Construction & Building Technology

Dynamic simulation on impact of surgeon bending movement on bacteria-carrying particles distribution in operating theatre

Tin-Tai Chow et al.

BUILDING AND ENVIRONMENT (2012)

Article Public, Environmental & Occupational Health

Predicting bacterial populations based on airborne particulates: A study performed in nonlaminar flow operating rooms during joint arthroplasty surgery

Gregory W. Stocks et al.

AMERICAN JOURNAL OF INFECTION CONTROL (2010)

Article Construction & Building Technology

On the applicability of the laminar flow index when selecting surgical lighting

W. A. C. Zoon et al.

BUILDING AND ENVIRONMENT (2010)

Article Public, Environmental & Occupational Health

Ventilation performance in the operating theatre against airborne infection: numerical study on an ultra-clean system

TT Chow et al.

JOURNAL OF HOSPITAL INFECTION (2005)

Article Construction & Building Technology

Performance of ventilation system in a non-standard operating room

TT Chow et al.

BUILDING AND ENVIRONMENT (2003)