4.7 Article

Buoyancy-driven natural ventilation characteristics of thermal corridors in industrial buildings

期刊

JOURNAL OF BUILDING ENGINEERING
卷 50, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.jobe.2022.104107

关键词

Industrial buildings; Thermal corridor; Buoyancy-driven natural ventilation; Heating plant; CFD simulation

资金

  1. Fundamental Research Funds for the Central Universities [2682020CX30]
  2. National Key Research and Development Program of China [2018YFC0705306]

向作者/读者索取更多资源

This study investigates the buoyancy-driven natural ventilation of a high-temperature corridor using computational fluid dynamics simulation. The height of the heat source bottom was found to have a significant effect on the indoor thermal environment.
The continuous setup of heating plants such as kilns and boilers may form thermal corridors in industrial buildings resulting in high air temperature, which could be harmful to workers. To solve these problems, this study presents an investigation of the buoyancy-driven natural ventilation of a high-temperature corridor via computational fluid dynamics (CFD) simulation. First, a field measurement was conducted in a typical thermal corridor of a ceramic factory to define the boundary conditions for the simulation. Then, a CFD model was established and validated using reduced-scaled model experimental data. Next, the flow and temperature fields of the thermal corridor under buoyancy-driven natural ventilation were examined using the verified model. It was shown that the natural ventilation in the side corridor is generated by an asymmetric heat channel, and the flow in the main corridor belongs to the natural convection of a semi-closed square heating cavity. Finally, the single-story industrial building aspect ratio was fixed at 3.3, and five different parameters of building and heating plant setups on the natural ventilation in corridors were analysed. For example, the heat source and air opening aspect ratios varied from 12.5 to 50 and from 25 to 100, respectively. The results indicated that the height of the heat source bottom has a more significant effect on the indoor thermal environment than other situations. The maximum ventilation flow rate was observed at the heat source position z(s)/H = 0.04 and opening position H-0/H = 0.05. When the overhead height z(s)/H reached 0.08, the flow in the main corridor turned to a symmetric heat channel, and the temperature in this region decreased sharply. This research can provide a reference for the natural ventilation design of high temperature corridors in factories.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据