4.6 Article

Medical Radiation Exposure Reduction in PET via Super-Resolution Deep Learning Model

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Review Radiology, Nuclear Medicine & Medical Imaging

Artificial intelligence for nuclear medicine in oncology

Kenji Hirata et al.

Summary: Artificial intelligence (AI) is increasingly used in nuclear medicine for oncology, providing functions such as assisting interpretation, providing additional information, and enhancing images. However, to apply AI to practical use, the harmonization between facilities and the possibility of black box explanations need to be resolved.

ANNALS OF NUCLEAR MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Digital PET/CT allows for shorter acquisition protocols or reduced radiopharmaceutical dose in [18F]-FDG PET/CT

Ian Alberts et al.

Summary: This study aimed to establish the feasibility of shorter acquisition times in digital PET/CT for tumor detection and lesion contrast. Results showed that new-generation digital PET scanners are able to produce clinically adequate images with shorter acquisitions, with only a small variation in semi-quantitative parameters.

ANNALS OF NUCLEAR MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Artificial intelligence enables whole-body positron emission tomography scans with minimal radiation exposure

Yan-Ran (Joyce) Wang et al.

Summary: The study utilized a novel artificial intelligence algorithm to generate diagnostic F-18-FDG PET images of pediatric cancer patients from ultra-low-dose input images. The convolutional neural network (CNN) successfully reconstructed standard-dose PET images from simulated ultra-low-dose scans, improving image quality and diagnostic accuracy compared to traditional low-dose scans. The CNN augmentation also led to higher agreement in diagnostic confidence between standard clinical scans and AI-reconstructed PET scans.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Revisiting detection of in-transit metastases in melanoma patients using digital 18F-FDG PET/CT with small-voxel reconstruction

Pierre-Andre Zimmermann et al.

Summary: Digital PET with small-voxel reconstruction provides extra value in detecting in-transit metastases in melanoma patients, reducing indeterminate findings and compensating for false negative scans with former generation PET systems. It is recommended to perform scans encompassing the appropriate upper or lower limbs of the patient.

ANNALS OF NUCLEAR MEDICINE (2021)

Review Computer Science, Information Systems

Deep Learning Algorithms for Single Image Super-Resolution: A Systematic Review

Yoong Khang Ooi et al.

Summary: This paper reviews the development of image super-resolution technology, focusing on convolutional neural network-based algorithms. Different algorithms were compared in terms of datasets used, loss functions, evaluation metrics, etc., with the advantages and disadvantages of each upsampling module and design technique summarized.

ELECTRONICS (2021)

Article Medicine, General & Internal

A Preliminary Study to Use SUVmax of FDG PET-CT as an Identifier of Lesion for Artificial Intelligence

Kenji Hirata et al.

Summary: This study aimed to localize lesions using SUVmax and found that when larger and more precise SUVmax values were given, fewer voxels satisfied the criterion. The local maximum restriction was effective in improving identifying performance.

FRONTIERS IN MEDICINE (2021)

Article Medicine, General & Internal

Evaluation of Arterial Spin Labeling MRI-Comparison with 15O-Water PET on an Integrated PET/MR Scanner

Markus Fahlstrom et al.

Summary: The study evaluated the similarity between CBFASL and CBFPET, showing a high correlation but insufficient agreement in absolute CBF values for ASL to be used interchangeably with O-15-water PET.

DIAGNOSTICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

The 2020 national diagnostic reference levels for nuclear medicine in Japan

Koichiro Abe et al.

ANNALS OF NUCLEAR MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Ultra-low-dose PET reconstruction using generative adversarial network with feature matching and task-specific perceptual loss

Jiahong Ouyang et al.

MEDICAL PHYSICS (2019)

Article Engineering, Biomedical

Whole-body PET estimation from low count statistics using cycle-consistent generative adversarial networks

Yang Lei et al.

PHYSICS IN MEDICINE AND BIOLOGY (2019)

Article Multidisciplinary Sciences

Machine learning algorithm validation with a limited sample size

Andrius Vabalas et al.

PLOS ONE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard

Ivo Rausch et al.

JOURNAL OF NUCLEAR MEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Performance Characteristics of the Digital Biograph Vision PET/CT System

Joyce van Sluis et al.

JOURNAL OF NUCLEAR MEDICINE (2019)

Review Radiology, Nuclear Medicine & Medical Imaging

PET/CT Lung Ventilation and Perfusion Scanning using Galligas and Gallium-68-MAA

Pierre-Yves Le Roux et al.

SEMINARS IN NUCLEAR MEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Reduction of 18F-FDG Dose in Clinical PET/MR Imaging by Using Silicon Photomultiplier Detectors

Tetsuro Sekine et al.

RADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Studies of a Next-Generation Silicon-Photomultiplier-Based Time-of-Flight PET/CT System

David F. C. Hsu et al.

JOURNAL OF NUCLEAR MEDICINE (2017)

Review Radiology, Nuclear Medicine & Medical Imaging

Clinical application of PET/MRI in oncology

Houman Sotoudeh et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2016)

Article Cardiac & Cardiovascular Systems

ASNC imaging guidelines/SNMMI procedure standard for positron emission tomography (PET) nuclear cardiology procedures

Vasken Dilsizian et al.

JOURNAL OF NUCLEAR CARDIOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Alexander M. Grant et al.

MEDICAL PHYSICS (2016)

Article Rehabilitation

A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research

Terry K. Koo et al.

JOURNAL OF CHIROPRACTIC MEDICINE (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0

Ronald Boellaard et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2015)

Article Multidisciplinary Sciences

Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT

Marcelo A. Queiroz et al.

PLOS ONE (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Whole-Body PET/CT Scanning: Estimation of Radiation Dose and Cancer Risk

Bingsheng Huang et al.

RADIOLOGY (2009)

Review Medicine, General & Internal

Current concepts - Computed tomography - An increasing source of radiation exposure

David J. Brenner et al.

NEW ENGLAND JOURNAL OF MEDICINE (2007)

Article Computer Science, Artificial Intelligence

Image quality assessment: From error visibility to structural similarity

Z Wang et al.

IEEE TRANSACTIONS ON IMAGE PROCESSING (2004)