This study compared the reliability and performance of Supersonic shear wave elastography (S-SWE) and Toshiba shear wave elastography (T-SWE) in diagnosing biliary atresia (BA) and assessing liver fibrosis. The results showed that T-SWE had good performances in the diagnosis of BA and the assessment of liver fibrosis compared with S-SWE. Furthermore, T-SWE showed higher measurement reproducibility than S-SWE.
Purpose: To compare the reliability and performance of Supersonic shear wave elastography (S-SWE) and Toshiba shear wave elastography (T-SWE) in the diagnosis of biliary atresia (BA) and assessment of liver fibrosis among jaundiced infants suspected of BA. Material and Methods: A total of 35 patients with suspected BA who underwent both S-SWE and T-SWE examinations were prospectively included. Diagnostic performances of S-SWE and T-SWE in identifying BA were evaluated. The correlation between two types of SWE values and histological liver fibrosis stages by Metavir scores were investigated in 21 patients with pathology results. The intraclass correlation coefficients (ICCs) were calculated in 16 patients for inter- and intra-observer agreement. The area under the receiver operating characteristic curve (AUC) analysis was compared using a DeLong test. Results: There were 22 patients with BA and 13 patients without BA. The diagnostic performance of S-SWE was comparable to that of T-SWE (AUC 0.895 vs. 0.822, p = 0.071) in diagnosing BA. The AUCs of S-SWE in predicting liver fibrosis stages were from 0.676 to 1.000 and showed no statistical differences from that of T-SWE (from 0.704 to 1.000, all p > 0.05). T-SWE provided higher inter-operator agreement (ICC 0.990) and intra-operator agreement (ICCs 0.966-0.993), compared with that of S-SWE in a previous study (ICC 0.980 for inter-operator and 0.930-0.960 for intra-operator). Conclusions: For infants suspected of BA, T-SWE had good performances in the diagnosis of BA and the assessment of liver fibrosis compared with S-SWE. Furthermore, T-SWE showed higher measurement reproducibility than S-SWE.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据