4.6 Article

Low-Cost Resistive Microfluidic Salinity Sensor for High-Precision Detection of Drinking Water Salt Levels

期刊

ACS OMEGA
卷 7, 期 18, 页码 15529-15539

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsomega.2c00268

关键词

-

资金

  1. Natural Sciences and Engineering Research Council of Canada (NSERC) [RGPIN-2020-06140]
  2. Ontario Ministry of Agriculture, Food and Rural Affairs (OMAFRA) [2018-0289]
  3. Early Researcher Award (ERA) [2019-0086]
  4. NSERC [RGPIN-2015-03666, RGPIN-202204605]

向作者/读者索取更多资源

This study optimized a low-cost microfluidic sensor for measuring water salinity in the range of 1-120 ppm. By improving the design, the sensor showed significant increases in sensitivity, detection range, and miniaturization of the microfluidic channel.
Rapid, inexpensive, and precise water salinity testing remains indispensable in water quality monitoring applications. Despite many sensors and commercialized devices to monitor seawater salinity, salt detection and quantification at very low levels of drinking water (below 120 ppm) have been overlooked. In this paper, we report on optimization of a low-cost microfluidic sensor to measure water salinity in the range of 1-120 ppm. The proposed design employs two copper microbridge wires suspended orthogonally in a PDMS microchannel to measure salinity based on the electrical resistance between the wires. The preliminary design of the sensor microchannel with a rectangular cross-section width (w) of 900 mu m and height (h) of 500 mu m could measure the water salinity in the range of 1-20 ppm in less than 1 min with detection sensitivity, limit of detection (LOD), and limit of quantification (LOQ) of 17.1 ohm/ohmmiddotcm, 0.31 ppm, and 0.37 ppm, respectively. Data from the preliminary design was used for developing and validating a numerical model which was subsequently used for parametric studies and optimization to improve the sensor's performance. The optimized design demonstrated an order of magnitude increase in sensitivity (385 ohm/ohmmiddotcm), a 6-fold wider detection range (1-120 ppm), and a 15-fold enhancement in miniaturization of the microfluidic channel (w = 200 mu m and h = 150 mu m) with LOD and LOQ of 0.39 and 0.44 ppm, respectively. In the future, the sensor can be integrated into a hand-held device to remove present impediments for low-cost and ubiquitous salinity surveillance of drinking water.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据