4.6 Article

Methylene Blue Near-Infrared Fluorescence Imaging in Breast Cancer Sentinel Node Biopsy

期刊

CANCERS
卷 14, 期 7, 页码 -

出版社

MDPI
DOI: 10.3390/cancers14071817

关键词

breast cancer; methylene blue; sentinel node biopsy; fluorescence

类别

资金

  1. Medical University of Gdansk [02-0013/07/114]
  2. Polish Ministry of Education and Science [DIR/WK/2017/01, 10/E-389/SPUB/SP/2020]

向作者/读者索取更多资源

This study is the first clinical series to propose the use of methylene blue as a fluorescent dye for breast cancer sentinel node biopsy. The study demonstrates the feasibility of using methylene blue as a fluorophore and suggests that dilution can improve fluorescence signal.
Simple Summary Currently the gold standard for sentinel node biopsy in breast cancer patients is radioactive nanocolloid and a blue dye. In the age of fluorescence guided surgery new fluorophores are used and methylene blue presents some fluorescent properties. This study is the first in a clinical series presenting the possible use of methylene blue as a fluorescent dye for the identification of sentinel nodes in breast cancer sentinel node biopsy. We presented a feasibility of this new method and also in additional experiments because of the quenching effect limitation, found possible dilution of methylene blue presenting improved fluorescence. Introduction: Fluorescence-based navigation for breast cancer sentinel node biopsy is a novel method that uses indocyanine green as a fluorophore. However, methylene blue (MB) also has some fluorescent properties. This study is the first in a clinical series presenting the possible use of MB as a fluorescent dye for the identification of sentinel nodes in breast sentinel node biopsy. Material and methods: Forty-nine patients with breast cancer who underwent sentinel node biopsy procedures were enrolled in the study. All patients underwent standard simultaneous injection of nanocolloid and MB. We visualized and assessed the sentinel nodes and the lymphatic channels transcutaneously, with and without fluorescence, and calculated the signal-to-background ratio (SBR). We also analyzed the corresponding fluorescence intensity of various dilutions of MB. Results: In twenty-three patients (46.9%), the location of the sentinel node, or the end of the lymphatic path, was visible transcutaneously. The median SBR for transcutaneous sentinel node location was 1.69 (range 1.66-4.35). Lymphatic channels were visible under fluorescence in 14 patients (28.6%) prior to visualization by the naked eye, with an average SBR of 2.01 (range 1.14-5.6). The sentinel node was visible under fluorescence in 25 patients (51%). The median SBR for sentinel node visualization with MB fluorescence was 2.54 (range 1.34-6.86). Sentinel nodes were visualized faster under fluorescence during sentinel node preparation. Factors associated with the rate of visualization included diabetes (p = 0.001), neoadjuvant chemotherapy (p = 0.003), and multifocality (p = 0.004). The best fluorescence was obtained using 40 mu M (0.0128 mg/mL) MB, but we also observed a clinically relevant dilution range between 20 mu M (0.0064 mg/mL) and 100 mu M (0.032 mg/mL). Conclusions: For the first time, we propose the clinical usage of MB as a fluorophore for fluorescence-guided sentinel node biopsy in breast cancer patients. The quenching effect of the dye may be the reason for its poor detection rate. Our analysis of different concentrations of MB suggests a need for a detailed clinical analysis to highlight the practical usefulness of the dye.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据