4.5 Article

4D flow MRI derived aortic hemodynamics multi-year follow-up in repaired coarctation with bicuspid aortic valve

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Cardiac & Cardiovascular Systems

Association of Regional Wall Shear Stress and Progressive Ascending Aorta Dilation in Bicuspid Aortic Valve

Gilles Soulat et al.

Summary: This study evaluated the predictive role of wall shear stress (WSS) in the growth of the ascending aorta (AAo). It found that higher rates of AAo dilation were associated with larger areas of elevated WSS in patients with bicuspid aortic valve (BAV), suggesting that measuring WSS can help identify BAV patients who require closer follow-up.

JACC-CARDIOVASCULAR IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Left ventricular diastolic early and late filling quantified from 4D flow magnetic resonance imaging

Yousef Alattar et al.

Summary: This study investigated the value of 4D flow MRI in measuring mitral filling and its correlation with TTE and 2D flow MRI. The results showed good agreement between 4D flow MRI and the reference methods in measuring flow rates and E/A ratios. The measurements using 4D flow MRI were reproducible and correlated with age and LV remodeling.

DIAGNOSTIC AND INTERVENTIONAL IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Investigation of Aortic Wall Thickness, Stiffness and Flow Reversal in Patients With Cryptogenic Stroke: A4DFlowMRIStudy

Kelly Jarvis et al.

Summary: This study used 4D flow MRI to assess the relationships between aortic stiffness, wall thickness, and flow reversal in patients with cryptogenic stroke and healthy controls. The results showed positive relationships between aortic pulse wave velocity, wall thickness, and flow reversal, supporting the hypothesis that aortic stiffness is involved in this retrograde embolic mechanism.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2021)

Review Radiology, Nuclear Medicine & Medical Imaging

CT evaluation of unrepaired/incidental congenital cardiovascular diseases in adults

Arash Bedayat et al.

Summary: Congenital heart disease affects approximately one million people in the USA, with the number increasing by 5% each year. Patients with complex CHD tend to be symptomatic and are diagnosed at a younger age than those with a single defect. Recent advances in computed tomography technology have led to more sensitive detection and diagnosis of CHD.

DIAGNOSTIC AND INTERVENTIONAL IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Fully automated 3D aortic segmentation of 4D flow MRI for hemodynamic analysis using deep learning

Haben Berhane et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Impact of age, sex, and global function on normal aortic hemodynamics

Michael B. Scott et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Interobserver agreement issues in radiology

M. Benchoufi et al.

DIAGNOSTIC AND INTERVENTIONAL IMAGING (2020)

Article Cardiac & Cardiovascular Systems

2018 AHA/ACC Guideline for the Management of Adults With Congenital Heart Disease: Executive Summary

Karen K. Stout et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2019)

Article Cardiac & Cardiovascular Systems

The Role of Imaging of Flow Patterns by 4D Flow MRI in Aortic Stenosis

Julio Garcia et al.

JACC-CARDIOVASCULAR IMAGING (2019)

Article Cardiac & Cardiovascular Systems

Interval changes in aortic peak velocity and wall shear stress in patients with bicuspid aortic valve disease

Ozair Rahman et al.

INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

In-vitro validation of 4D flow MRI measurements with an experimental pulsatile flow model

A. David et al.

DIAGNOSTIC AND INTERVENTIONAL IMAGING (2019)

Review Cardiac & Cardiovascular Systems

Diagnosis, imaging and clinical management of aortic coarctation

Elles J. Dijkema et al.

Article Cardiac & Cardiovascular Systems

Survival and cardiovascular events after coarctation-repair in long-term follow-up (COAFU): Predictive value of clinical variables

P. Bambul Heck et al.

INTERNATIONAL JOURNAL OF CARDIOLOGY (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta

Pim van Ooij et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI

Michael J. Rose et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2016)

Article Cardiac & Cardiovascular Systems

Valve-Related Hemodynamics Mediate Human Bicuspid Aortopathy Insights From Wall Shear Stress Mapping

David G. Guzzardi et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2015)

Article Engineering, Biomedical

Characterization of Abnormal Wall Shear Stress Using 4D Flow MRI in Human Bicuspid Aortopathy

Pim van Ooij et al.

ANNALS OF BIOMEDICAL ENGINEERING (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

Volumetric Arterial Wall Shear Stress Calculation Based on Cine Phase Contrast MRI

Wouter V. Potters et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2015)

Article Cardiac & Cardiovascular Systems

2014 ESC Guidelines on the diagnosis and treatment of aortic diseases

Raimund Erbel et al.

EUROPEAN HEART JOURNAL (2014)

Review Cardiac & Cardiovascular Systems

Aortic Coarctation Repair in the Adult

Goncalo Cardoso et al.

JOURNAL OF CARDIAC SURGERY (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Determinants and Normal Values of Ascending Aortic Diameter by Age, Gender, and Race/Ethnicity in the Multi-Ethnic Study of Atherosclerosis (MESA)

Evrim B. Turkbey et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2014)

Article Cardiac & Cardiovascular Systems

Pressure Fields by Flow-Sensitive, 4D, Velocity-Encoded CMR in Patients With Aortic Coarctation

Eugenie Riesenkampff et al.

JACC-CARDIOVASCULAR IMAGING (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Aortic Hemodynamics in Patients With and Without Repair of Aortic Coarctation In Vivo Analysis by 4D Flow-Sensitive Magnetic Resonance Imaging

Alex Frydrychowicz et al.

INVESTIGATIVE RADIOLOGY (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

In Vivo Noninvasive 4D Pressure Difference Mapping in the Human Aorta: Phantom Comparison and Application in Healthy Volunteers and Patients

Jelena Bock et al.

MAGNETIC RESONANCE IN MEDICINE (2011)

Article Radiology, Nuclear Medicine & Medical Imaging

Clinical Evaluation of Aortic Coarctation With 4D Flow MR Imaging

Michael D. Hope et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2010)

Article Cardiac & Cardiovascular Systems

A classification system for the bicuspid aortic valve from 304 surgical specimens

Hans-H. Sievers et al.

JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY (2007)

Article Cardiac & Cardiovascular Systems

Normal vascular aging: Differential effects on wave reflection and aortic pulse wave velocity - The Anglo-Cardiff Collaborative Trial (ACCT)

CM McEniery et al.

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY (2005)

Article Cardiac & Cardiovascular Systems

Usefulness of MRI in the follow-up of patients with repaired aortic coarctation and bicuspid aortic valve

JP Quenot et al.

INTERNATIONAL JOURNAL OF CARDIOLOGY (2005)