4.6 Article

Multi-View 3D Transesophageal Echocardiography Registration and Volume Compounding for Mitral Valve Procedure Planning

期刊

APPLIED SCIENCES-BASEL
卷 12, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/app12094562

关键词

compounded echocardiography; volume stitching; 3D registration; mosaicing; 3D TEE; mitral valve; monogenic signal

资金

  1. Canadian Foundation for Innovation [CFI-20994, 36199]
  2. Natural Science and Engineering Research Council of Canada NSERC RPGIN [2014-04504]
  3. Canadian Institutes for Health Research CIHR FDN [143232]
  4. Academic Medical Organization of Southwestern Ontario

向作者/读者索取更多资源

Three-dimensional ultrasound mosaicing technique can improve image quality and expand the field of view for cardiac procedures, particularly for mitral valve operations. This study proposes a new compounding technique that utilizes multiple ultrasound volumes from different positions to reconstruct high-detail images of the mitral valve and sub-valvular structures. The technique has been validated using excised porcine mitral valve units and patient data, demonstrating its accuracy in capturing the physical structures present.
Three-dimensional ultrasound mosaicing can increase image quality and expand the field of view. However, limited work has been done applying these compounded approaches for cardiac procedures focused on the mitral valve. For procedures targeting the mitral valve, transesophageal echocardiography (TEE) is the primary imaging modality used as it provides clear 3D images of the valve and surrounding tissues. However, TEE suffers from image artefacts and signal dropout, particularly for structures lying below the valve, including chordae tendineae, making it necessary to acquire alternative echo views to visualize these structures. Due to the limited field of view obtainable, the entire ventricle cannot be directly visualized in sufficient detail from a single image acquisition in 3D. We propose applying an image compounding technique to TEE volumes acquired from a mid-esophageal position and several transgastric positions in order to reconstruct a high-detail volume of the mitral valve and sub-valvular structures. This compounding technique utilizes both fully and semi-simultaneous group-wise registration to align the multiple 3D volumes, followed by a weighted intensity compounding step based on the monogenic signal. This compounding technique is validated using images acquired from two excised porcine mitral valve units and three patient data sets. We demonstrate that this compounding technique accurately captures the physical structures present, including the mitral valve, chordae tendineae and papillary muscles. The chordae length measurement error between the compounded ultrasound and ground-truth CT for two porcine valves is reported as 0.7 +/- 0.6 mm and 0.6 +/- 0.6 mm.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据